{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-0HM36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-0HM36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-0HM36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-0HM36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA series, Molded case circuit breaker, order code 3VA2116-0HM36-0AA0, 3-pole, 160 A, ETU330 electronic trip unit, 440 kA at 415 V, IP40 front.","salesMarkdown":"## 160 A MCCB with ETU330 — selectivity and coordination for main feeders The Siemens SENTRON 3VA2116-0HM36-0AA0 is a 3-pole molded case circuit breaker rated for 160 A continuous current across the full operating temperature range from 40 °C to 70 °C — no derating needed. That makes it a straight drop for a main feeder or large subfeed where you need the full ampacity at elevated panel ambient. It carries the ETU330 electronic trip unit with adjustable long-time pickup (I_g) from 32 A to 160 A and short-time/instantaneous pickup (I_i) up to 1,600 A. Panel integration: the 86 mm depth, 105 mm width, and 181 mm height fit standard SENTRON 3VA mounting footprints. Front IP40 protection covers the trip unit and nameplate; the breaker is rated for an isolation voltage of 800 V. Maximum power loss is 19.7 W. An optional motor drive (product extension) is available for remote operation. ## Temperature and environmental ratings Operating ambient: -25 °C to 70 °C. ## Trip unit and protection settings The ETU330 electronic trip unit provides LSI protection (long-time, short-time, instantaneous). The adjustable long-time pickup range (32–160 A) lets you match cable ampacity without swapping the breaker frame. Short-time/instantaneous pickup adjustable up to 1,600 A. Ground-fault monitoring is available via summation current formation on the line conductor.","metaTitle":"Siemens 3VA2116-0HM36-0AA0 SENTRON MCCB, 160 A, 3-Pole, ETU3","metaDescription":"Siemens SENTRON 3VA2116-0HM36-0AA0 molded case circuit breaker, 160 A, 3-pole, ETU330 trip unit. Breaking capacity 440 kA at 415 V. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","title":"3VA2116-0HM36-0AA0","Height":"181 mm","at 415 V":"440 kA","at 690 V":"187 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","description":"circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 3-pole, line protection ETU330, LIG, In=160A overload protection Ir=63A... 160A short circuit protection Ii=1,5... 10 x In ground fault protection Ig=0,2... 1 x In, tg=0,1/0,3s cable connection","Trip Indicator":"No","Number Of Poles":"3","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"19.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"160 A","Ground-Fault Monitoring Version":"Summation current formation L-conductor","Tension assignée d'isolement Ui":"800 V","Design Of The Overcurrent Release":"ETU330","protection class IP / on the front":"IP40","reference code / acc. to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / lg max.":"160 A","Adjustable response value current / lg min.":"32 A","Adjustable response value current / li max.":"1 600 A","Adjustable response value current / li min.":"240 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LIG","number of CO contacts / for auxiliary contacts":"0","Max. rated operational current of the frame size":"160 A","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1417416&mlfb=3VA2116-0HM36-0AA0"},"ai":{"faq":[{"question":"Where can I buy 3VA2116-0HM36-0AA0 and how is it quoted?","answer":"It is available through independent distribution, quoted to order against an RFQ. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of 3VA2116-0HM36-0AA0 at 415 V?","answer":"440 kA at 415 V, and 187 kA at 690 V."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-0HM36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-0HM36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}