{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-0HN46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-0HN46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-0HN46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-0HN46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2116-0HN46-0AA0, molded case circuit breaker, 4-pole, 160 A continuous, ETU350 release, 440 kA at 415 V AC, 187 kA at 690 V AC.","salesMarkdown":"The 3VA2116-0HN46-0AA0 is a Siemens SENTRON molded case circuit breaker (MCCB) rated for 160 A continuous current, with a maximum breaking capacity of 440 kA at 415 V AC and 187 kA at 690 V AC. The N-conductor protection is configurable to OFF, 50%, or 100% of the phase current — useful for sizing the neutral on systems with harmonic content. There is no official successor order code — the part is current, not replaced. If you need a functional cross-reference within the same SENTRON 3VA family, the closest peer is the 3VA1112-5EE32-0AA0, but that is a different frame size and rating; the 3VA2116-0HN46-0AA0 is the 160 A, 4-pole variant with the high-breaking ETU350 release. Do not assume a drop-in swap without checking the frame dimensions and terminal layout. At 86 mm deep, this MCCB fits standard 200 mm deep switchboards with clearance for rear-connected busbars. The 140 mm width is a 4-pole frame — plan for a 4-module wide cutout in the mounting plate. Maximum power loss is 19.7 W, so ventilation in the enclosure should account for that heat at full load.","metaTitle":"Siemens 3VA2116-0HN46-0AA0 SENTRON MCCB, 160 A, 440 kA at 41","metaDescription":"Siemens SENTRON 3VA2116-0HN46-0AA0 molded case circuit breaker, 160 A continuous, 440 kA breaking capacity at 415 V AC, 4-pole, ETU350 release. Current lifecycle status. Quoted to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"140 mm","title":"3VA2116-0HN46-0AA0","Height":"181 mm","Maximum":"1 600 A","Minimum":"240 A","at 415 V":"440 kA","at 690 V":"187 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Depth [In]":"3.39 in","Width [In]":"5.51 in","Height [In]":"7.13 in","description":"circuit breaker 3VA2 IEC frame 160 breaking capacity class E Icu=200 kA @ 415 V 4-pole, line protection ETU350, LSI, In=160A overload protection Ir=63A... 160A short circuit protection Isd=1,5...10xIr, Ii=12xIn neutral protection adjustable(OFF 50% 100%) cable connection","Trip Indicator":"No","Number Of Poles":"4","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"19.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"160 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 50%; 100%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"E","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1417422&mlfb=3VA2116-0HN46-0AA0"},"ai":{"faq":[{"question":"Where can I buy 3VA2116-0HN46-0AA0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the breaking capacity of 3VA2116-0HN46-0AA0 at 415 V and 690 V?","answer":"The breaking capacity is 440 kA at 415 V AC and 187 kA at 690 V AC. The 440 kA figure is exceptionally high — suitable for installations with very high available fault current, such as large transformer secondaries or industrial main switchboards."},{"question":"Does 3VA2116-0HN46-0AA0 have an undervoltage release or communication function?","answer":"No. This breaker has no undervoltage release and no communication function. It also lacks ground-fault monitoring. It is a basic line-protection MCCB with an electronic trip unit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-0HN46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-0HN46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}