{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-5HL32-0AC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-5HL32-0AC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-5HL32-0AC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5HL32-0AC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2116-5HL32-0AC0, Molded case circuit breaker, 3-pole, 160 A, interrupting 187 kA at 240 V, 121 kA at 415 V.","salesMarkdown":"## MCCB for line protection with high interrupting capacity The Siemens SENTRON 3VA2116-5HL32-0AC0 is a 3-pole molded case circuit breaker (MCCB) rated for 160 A continuous current, designed for line protection in distribution panels. Its interrupting capacity hits 187 kA at 240 V and 121 kA at 415 V — enough to handle high-fault scenarios without cascading upstream. The 800 V rated insulation voltage gives headroom for 480 V or 600 V class systems. Dimensions are 181 mm high, 105 mm wide, 86 mm deep — fits standard MCCB panel cutouts. ## Current rating holds across temperature range Unlike many MCCBs that derate above 40 °C, this unit holds its 160 A rating all the way to 70 °C ambient (–). That means no oversizing needed for a hot panel — useful in a crowded enclosure or near a heat source.","metaTitle":"Siemens SENTRON 3VA2116-5HL32-0AC0 MCCB, 160 A, 3-Pole, 187","metaDescription":"Siemens SENTRON 3VA2116-5HL32-0AC0 molded case circuit breaker, 160 A continuous, 3-pole, 187 kA interrupting at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 600 A","Minimum":"240 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21165HL320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"160 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=37633&mlfb=3VA2116-5HL32-0AC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5HL32-0AC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2116-5HL32-0AC0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is 3VA2116-5HL32-0AC0's listed depth (86 mm) on this component line?","answer":"The listed depth is 86 mm (3.39 in), width 105 mm (4.13 in), height 181 mm (7.13 in) — fits standard MCCB panel cutouts."},{"question":"What is 3VA2116-5HL32-0AC0's interrupting capacity at 240 V?","answer":"At 240 V the interrupting capacity is 187 kA; at 415 V and 440 V it's 121 kA, at 500 V it's 75.6 kA, and at 690 V it's 3.7 kA."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-5HL32-0AC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-5HL32-0AC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}