{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-5HL32-0CC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-5HL32-0CC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-5HL32-0CC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5HL32-0CC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2116-5HL32-0CC0, molded case circuit breaker, 3-pole, 160 A continuous, line-protection design, with undervoltage release and 2 auxiliary switches HQ.","salesMarkdown":"## Siemens 3VA2116-5HL32-0CC0 — 160 A SENTRON MCCB for Line Protection Breaking capacity runs 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V, so it handles high-fault commercial and industrial service entrances where the available short-circuit current is substantial. That simplifies BOM sizing: the breaker carries its full nameplate current even in a warm enclosure. The 3-pole line-protection design means it's configured for ungrounded or corner-grounded delta systems, not for solidly-grounded wye with a separate neutral pole. ## Breaking Capacity by Voltage — One Breaker, Multiple Fault Levels This MCCB carries a single interrupting rating that varies by system voltage: 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. The breaker's physical footprint is 181 mm high, 105 mm wide, 86 mm deep — standard for a 160 A frame in the SENTRON 3VA2 family.","metaTitle":"Siemens 3VA2116-5HL32-0CC0 SENTRON MCCB, 160 A, 3-Pole, 187","metaDescription":"Siemens SENTRON 3VA2116-5HL32-0CC0 molded case circuit breaker, 160 A continuous, 3-pole, 187 kA breaking at 240 V. Active production. Sourced to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 600 A","Minimum":"240 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"28 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21165HL320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"160 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB24","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=399544&mlfb=3VA2116-5HL32-0CC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5HL32-0CC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2116-5HL32-0CC0 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"Will 3VA2116-5HL32-0CC0 drop into a panel specified around 3VA2116-5HL32-0AK0 without rewiring?","answer":"Both are 3-pole 160 A SENTRON MCCBs in the same 3VA2 frame with identical dimensions (181 x 105 x 86 mm), so the physical fit and bus-bar spacing are the same. The difference is in the internal accessories: -0CC0 carries an undervoltage release and two auxiliary switches HQ, while -0AK0 has a different auxiliary switch configuration. Check the auxiliary contact wiring before assuming a drop-in swap."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-5HL32-0CC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-5HL32-0CC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}