{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-5HL36-0BC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-5HL36-0BC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-5HL36-0BC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5HL36-0BC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA2 IEC frame 160, breaking capacity class M, Icu=55kA @ 415V, 3-pole, line protection ETU320 LI, In=160A, Ir=63A...160A, Ii=1.5...10 x In, clamp connection, undervoltage release 24V DC, 2 auxiliary switches HQ.","salesMarkdown":"## What this breaker carries — and what that means for the panel The 3VA2116-5HL36-0BC0 is a Siemens 3VA2 IEC frame 160 circuit breaker in breaking capacity class M, rated Icu=55kA at 415 VAC. Three-pole construction, line-side protection via an ETU320 trip unit with LI (long-time and instantaneous) curves. In=160 A continuous rating, with overload protection adjustable Ir=63 A...160 A and short-circuit pickup Ii=1.5...10 x In. The clamp-type terminals accept copper or aluminum conductors up to the frame's rated cross-section — no compression lugs needed for most panel builds. ## Integrated accessories — UVR and auxiliary switches Because the UVR and aux switches are installed at the factory, no field wiring into the breaker's accessory slots is required; the terminations are accessible on the front face for control wiring.","metaTitle":"3VA2116-5HL36-0BC0 Siemens 3VA2 IEC Frame 160, 55kA @ 415V,","metaDescription":"Siemens 3VA2116-5HL36-0BC0 circuit breaker, IEC frame 160, breaking capacity class M Icu=55kA @ 415V, 3-pole, ETU320 LI, In=160A, UVR 24V DC, 2 aux switches. Active production, ava","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=338713&mlfb=3VA2116-5HL36-0BC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5HL36-0BC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2116-5HL36-0BC0 and what is the lead time?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here, but we can provide a firm quote on request."},{"question":"What does the ETU320 LI trip unit protect against?","answer":"The ETU320 LI provides long-time (overload) protection with adjustable Ir from 63 A to 160 A, and instantaneous (short-circuit) protection with adjustable Ii from 1.5 to 10 times the rated current In=160 A. It does not include ground-fault protection — that would require an ETU3xx G variant."},{"question":"What is the breaking capacity of this breaker at 415 V?","answer":"The 3VA2116-5HL36-0BC0 has an Icu of 55 kA at 415 VAC, which is the class M (medium) breaking capacity in the 3VA2 frame 160 series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-5HL36-0BC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-5HL36-0BC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}