{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-5HL36-0CA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-5HL36-0CA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-5HL36-0CA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5HL36-0CA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2116-5HL36-0CA0, molded case circuit breaker, 3-pole, 160 A rated continuous current Iu, ETU320 electronic trip unit, line protection version, with undervoltage release.","salesMarkdown":"Breaking capacity ranges from 187 kA at 240 V down to 4.25 kA at 690 V, so at typical 415 V line-to-line it interrupts 121 kA — enough for high-fault utility feeds without cascading upstream breakers. Dimensions are 105 mm wide by 181 mm tall by 86 mm deep — standard 3-pole MCCB footprint for a 160 A frame. No auxiliary contact block, no voltage trigger, no ground-fault monitoring, and no communication module are included on this variant. If you need those, the base switch (3VA2116-5HL36-0AA0) accepts field-installable accessories. Mechanical endurance is rated at 20,000 operations — typical for a distribution breaker not cycled daily; for frequent switching duty, consider a contactor in series. The storage minimum matters for unheated warehouses in cold climates; the operating maximum governs derating in hot enclosures.","metaTitle":"Siemens 3VA2116-5HL36-0CA0 SENTRON MCCB, 160 A, 3-Pole, ETU3","metaDescription":"Siemens 3VA2116-5HL36-0CA0 SENTRON molded case circuit breaker, 160 A continuous, 3-pole, ETU320 trip unit, 187 kA at 240 V. Active production, sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"4.25 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"154 A","at 60 °C":"148 A","at 65 °C":"142 A","at 70 °C":"136 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"28 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"160 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2116-5HL36-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB24","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"160 A","Adjustable response value current / li max.":"1 600 A","Adjustable response value current / li min.":"240 A","Adjustable response value current / lr min.":"63 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=245516&mlfb=3VA2116-5HL36-0CA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5HL36-0CA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2116-5HL36-0CA0 and get a price?","answer":"This MCCB is sourced and quoted to order. Submit an RFQ through this listing; availability and current pricing are confirmed at quote time. No stock or price figures are published here."},{"question":"Does 3VA2116-5HL36-0CA0 include an undervoltage release?","answer":"Yes, it ships with an integrated undervoltage release (UVR), part number 3VA9608-0BB24, that trips the breaker when control voltage drops below the dropout threshold."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-5HL36-0CA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-5HL36-0CA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}