{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-5HL36-0CL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-5HL36-0CL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-5HL36-0CL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5HL36-0CL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2116-5HL36-0CL0, molded case circuit breaker, 3-pole, 160 A continuous, line protection, 86 x 105 x 181 mm.","salesMarkdown":"The Siemens SENTRON 3VA2116-5HL36-0CL0 is a 3-pole molded case circuit breaker rated 160 A continuous across the full -25 °C to 70 °C operating range — no derating curve to chase above 40 °C. The interrupting ratings are the headline: 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. ## Auxiliaries and release — what's inside the can That's enough status feedback for a PLC input card without adding external relays. The UVR means the breaker trips on loss of control voltage — standard for safety disconnects or emergency-stop chains where you want the main breaker to drop when the E-stop button is pressed. The 105 mm width is the same as the 3VA2 fixed-thermal family, so a panel laid out for a 160 A 3VA2 will accept this 5HL36 variant without re-drilling the mounting plate.","metaTitle":"Siemens 3VA2116-5HL36-0CL0 SENTRON MCCB, 160 A, 3-Pole, Line","metaDescription":"Siemens SENTRON 3VA2116-5HL36-0CL0 molded case circuit breaker, 160 A continuous, 3-pole, line protection. SCCR 187 kA at 240 V. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 600 A","Minimum":"240 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"28 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21165HL360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"160 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB24","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=152318&mlfb=3VA2116-5HL36-0CL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5HL36-0CL0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2116-5HL36-0CL0?","answer":"Pricing and availability are confirmed at quote time. Submit an RFQ through this listing; we source through independent distribution and quote to order."},{"question":"Will 3VA2116-5HL36-0CL0 drop into a panel specified around 3VA2116-5HL32-0AK0?","answer":"The 105 mm width and 181 mm height match the 3VA2 fixed-thermal family footprint, so it fits the same panel cutout and bus bar spacing as the 3VA2116-5HL32-0AK0. The auxiliary switch count and UVR are the same, so wiring the control circuit is a straight swap."},{"question":"What compliance documentation does Siemens provide for 3VA2116-5HL36-0CL0?","answer":"Siemens SENTRON MCCBs carry UL 489, CSA C22.2 No. 5, and IEC 60947-2 certifications. RoHS and REACH declarations are available through Siemens Industry Online Support."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-5HL36-0CL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-5HL36-0CL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}