{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-5HN32-0KA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-5HN32-0KA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-5HN32-0KA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5HN32-0KA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 MCCB, line protection, 3-pole, 160 A, ETU350 electronic trip unit, shunt trip (STL), 86 mm depth, 105 mm width, 181 mm height.","salesMarkdown":"## SENTRON 3VA2116-5HN32-0KA0 — 160 A MCCB with ETU350 and Shunt Trip The interrupting ratings climb to 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V — so this breaker handles high-fault utility feeds or transformer secondaries where the available fault current is substantial. The thermal derating curve is flat from 40 °C through 50 °C — still 160 A — then drops to 154 A at 55 °C, 148 A at 60 °C, 142 A at 65 °C, and 136 A at 70 °C. The supplied basic switch is 3VA2116-5HN32-0AA0. Footprint is 105 mm wide by 181 mm tall by 86 mm deep — standard SENTRON 3VA2 frame size for 160 A. Bolts directly to a backplate or mounts on a DIN rail adapter (not included). The 3-pole block leaves room for side-mounted accessories; the shunt trip occupies the auxiliary release slot, so no room for a second release without a different config. Latching endurance is rated 20,000 cycles, which is typical for a distribution MCCB — not a motor-switching duty cycle, but fine for infrequent manual switching or remote shunt-trip operation.","metaTitle":"Siemens 3VA2116-5HN32-0KA0 SENTRON MCCB, 160 A, 3-Pole, ETU3","metaDescription":"Siemens 3VA2116-5HN32-0KA0 SENTRON MCCB, 160 A continuous, 3-pole, ETU350 electronic trip, shunt trip release. SCCR 187 kA at 240 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"4.25 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"154 A","at 60 °C":"148 A","at 65 °C":"142 A","at 70 °C":"136 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"25.5 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"160 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2116-5HN32-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL33","Design of the overcurrent release":"ETU350","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.4 s","Adjustable response value time / tsd min.":"0.02 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"160 A","Adjustable response value current / li max.":"1 600 A","Adjustable response value current / li min.":"1 600 A","Adjustable response value current / lr min.":"63 A","Adjustable response value current / Isd max.":"1 600 A","Adjustable response value current / Isd min.":"240 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LSI","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=467635&mlfb=3VA2116-5HN32-0KA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5HN32-0KA0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting rating of 3VA2116-5HN32-0KA0 at 240 V?","answer":"187 kA at 240 V, dropping to 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V."},{"question":"Will 3VA2116-5HN32-0KA0 drop into a panel specified around 3VA1010-2ED32-0JA0 without rewiring?","answer":"Not directly — the 3VA2116-5HN32-0KA0 is a 160 A frame with a shunt trip, while the 3VA1010-2ED32-0JA0 is a different frame size and trip configuration. Panel cutouts, bus bar spacing, and accessory slots differ; verify the footprint before swapping."},{"question":"Where can I buy 3VA2116-5HN32-0KA0 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures or prices on this page."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-5HN32-0KA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-5HN32-0KA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}