{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-5JP36-0AF0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-5JP36-0AF0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-5JP36-0AF0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5JP36-0AF0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, Molded case circuit breaker, 3VA2116-5JP36-0AF0, 3-pole, 160 A, ETU550 electronic trip unit, line protection version.","salesMarkdown":"The Siemens 3VA2116-5JP36-0AF0 is a SENTRON molded case circuit breaker (MCCB) in the 3VA2 series, configured as a 3-pole line protection device with an ETU550 electronic trip unit. It carries a rated continuous current (Iu) of 160 A across the full ambient temperature range from 40 °C through 70 °C — no derating needed up to that ceiling, which simplifies panel thermal budgeting. The breaking capacity figures tell you where it can sit in a fault-current study: 187 kA at 240 V, 121 kA at 415 V and 440 V, 76 kA at 500 V, and 3.8 kA at 690 V. Footprint is 105 mm wide by 181 mm tall by 86 mm deep — a standard 3-pole MCCB form factor for DIN-rail or direct-panel mounting. ## Environmental and endurance specs Operating temperature range is -25 °C to 70 °C; storage range extends from -40 °C to 80 °C. Mechanical endurance is rated at 20,000 operations.","metaTitle":"Siemens 3VA2116-5JP36-0AF0 SENTRON MCCB, 160 A, 3-pole, ETU5","metaDescription":"Siemens 3VA2116-5JP36-0AF0 SENTRON molded case circuit breaker. 160 A rated current, 3-pole, ETU550 release. Breaking capacity 187 kA at 240 V. Active production. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"76 kA","at 690 V":"3.8 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Width [in]":"4.1 in","Height [in]":"7.1 in","Number of poles":"3","Product version":"Line protection","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"25.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"160 A","Rated insulation voltage Ui":"800 V","Ground fault monitoring version":"Without","Design of the overcurrent release":"ETU550","Protection class IP / on the front":"IP40","Design of the N-conductor protection":"Without","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"20","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"160 A","Adjustable response value current / li max.":"1 600 A","Adjustable response value current / li min.":"240 A","Adjustable response value current / lr min.":"64 A","Adjustable response value current / Isd max.":"1 600 A","Adjustable response value current / Isd min.":"96 A","Neutral conductors / upgradeable/retrofittable":"Yes","Protective function of the overcurrent release":"LSI","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=620573&mlfb=3VA2116-5JP36-0AF0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5JP36-0AF0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2116-5JP36-0AF0 at 415 V?","answer":"121 kA at 415 V, which is also the rating at 440 V. At 240 V it reaches 187 kA, at 500 V it is 76 kA, and at 690 V it is 3.8 kA."},{"question":"Where can I buy 3VA2116-5JP36-0AF0?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or price figures are published here."},{"question":"Does 3VA2116-5JP36-0AF0 have a communication function?","answer":"Yes, communication function is built in, which means it can integrate with monitoring and control systems via the ETU550 trip unit's communication capabilities."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-5JP36-0AF0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-5JP36-0AF0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}