{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-5JQ32-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-5JQ32-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-5JQ32-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5JQ32-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2116-5JQ32-0DA0, molded case circuit breaker, 3-pole, 160 A, line protection, ETU560 electronic trip unit, 187 kA at 240 V, 121 kA at 415 V.","salesMarkdown":"The Siemens 3VA2116-5JQ32-0DA0 is a 3-pole SENTRON molded case circuit breaker rated for 160 A continuous current at 40 °C, with an ETU560 electronic trip unit configured for line protection. Its interrupting capacity reaches 187 kA at 240 V AC and 121 kA at both 415 V and 440 V — figures that put it squarely in high-fault-duty distribution, not just branch protection. At 500 V it still holds 79 kA, and at 690 V it drops to 4.25 kA, so the application voltage governs the SCCR you can claim on the panel label. ## Current derating — the real continuous rating at your ambient At 55 °C it derates to 154 A, at 60 °C to 148 A, at 65 °C to 142 A, and at 70 °C to 136 A. ## Built-in undervoltage release and communication This variant includes an undervoltage release (UVR) — design designation 3VA9608-0BB25 — and a communication function, so it can be integrated into a higher-level monitoring or shutdown scheme without adding an external relay. The overcurrent release is the ETU560, a programmable electronic trip unit that supports adjustable pickup and delay settings for selectivity coordination. There is no auxiliary contact version on this order code, so if you need a remote status signal, plan for an external auxiliary switch block. ## Mounting dimensions and panel fit","metaTitle":"Siemens 3VA2116-5JQ32-0DA0 SENTRON MCCB, 160 A, 3-Pole, 187","metaDescription":"Siemens 3VA2116-5JQ32-0DA0 SENTRON molded case circuit breaker, 160 A rated continuous current, 3-pole, line protection, ETU560 release, 187 kA at 240 V. Active production. Quoted","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"4.25 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"154 A","at 60 °C":"148 A","at 65 °C":"142 A","at 70 °C":"136 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"Yes","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"28 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"160 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2116-5JQ32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Summation current formation L-conductor","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"ETU560","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"20","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"160 A","Adjustable response value current / lg max.":"160 A","Adjustable response value current / lg min.":"32 A","Adjustable response value current / li max.":"1 600 A","Adjustable response value current / li min.":"240 A","Adjustable response value current / lr min.":"64 A","Adjustable response value current / Isd max.":"1 600 A","Adjustable response value current / Isd min.":"96 A","Ground fault protection can be switched ON/OFF":"Yes","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LSIG","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=269011&mlfb=3VA2116-5JQ32-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5JQ32-0DA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2116-5JQ32-0DA0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for a firm price and availability confirmation."},{"question":"What is 3VA2116-5JQ32-0DA0's listed depth?","answer":"The depth is 86 mm, with a width of 105 mm and height of 181 mm."},{"question":"What compliance documentation does this brand provide for 3VA2116-5JQ32-0DA0?","answer":"As a SENTRON molded case circuit breaker, it is designed to meet IEC 60947-2 and UL 489 standards. RoHS and REACH declarations are typically available from Siemens documentation. Specific certification marks (CE, UKCA, EAC) should be verified against the nameplate for the shipped variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-5JQ32-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-5JQ32-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}