{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-5JQ32-0DL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-5JQ32-0DL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-5JQ32-0DL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5JQ32-0DL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2116-5JQ32-0DL0, 3-pole molded case circuit breaker, 160 A rated continuous current, breaking capacity 187 kA at 240 V AC, with ETU560 electronic trip unit, undervoltage release, ground-fault monitoring, and communication function.","salesMarkdown":"The breaking capacity climbs to 187 kA at 240 V AC and stays at 121 kA through 440 V AC — at 690 V it drops to 4.25 kA, so this is a high-interrupting-capacity frame sized for low-voltage main feeders or large subfeeds where fault current is high. Temperature derating is already baked in: at 40 °C through 50 °C it holds the full 160 A; at 55 °C it drops to 154 A, and at 70 °C it's 136 A. The ETU560 is a microprocessor-based release with LSI (long-time, short-time, instantaneous) protection curves, plus ground-fault monitoring via summation current on the L-conductor. Communication function is built in, so the breaker can report status and trip events to a higher-level system. That's enough to signal remote status without adding an external contact block. Dimensions are 105 mm wide, 181 mm high, 86 mm deep — a standard 3-pole MCCB footprint for a 160 A frame. Power loss is 28 W maximum at rated current; factor that into the enclosure thermal budget if the panel is sealed. The basic switch is order code 3VA2116-5JQ32-0AA0, and the integrated auxiliary trip is 3VA9608-0BB25 — these are the internal sub-assemblies if you ever need a replacement release or contact module.","metaTitle":"Siemens 3VA2116-5JQ32-0DL0 MCCB, 160 A, 3-Pole, 187 kA at 24","metaDescription":"Siemens SENTRON 3VA2116-5JQ32-0DL0 molded case circuit breaker, 160 A, 3-pole, breaking capacity 187 kA at 240 V AC. ETU560 trip unit, UVR, ground-fault monitoring. Sourced to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"4.25 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"154 A","at 60 °C":"148 A","at 65 °C":"142 A","at 70 °C":"136 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"Yes","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"28 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"160 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2116-5JQ32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Summation current formation L-conductor","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"ETU560","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"20","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"160 A","Adjustable response value current / lg max.":"160 A","Adjustable response value current / lg min.":"32 A","Adjustable response value current / li max.":"1 600 A","Adjustable response value current / li min.":"240 A","Adjustable response value current / lr min.":"64 A","Adjustable response value current / Isd max.":"1 600 A","Adjustable response value current / Isd min.":"96 A","Ground fault protection can be switched ON/OFF":"Yes","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"4","Protective function of the overcurrent release":"LSIG","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=226207&mlfb=3VA2116-5JQ32-0DL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5JQ32-0DL0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2116-5JQ32-0DL0?","answer":"The part is sourced to order through independent distribution. Submit an RFQ for a confirmed price and lead time; availability is verified at quote time."},{"question":"What is the breaking capacity of 3VA2116-5JQ32-0DL0 at 240 V?","answer":"187 kA at 240 V AC. At 415 V and 440 V it is 121 kA; at 500 V it is 79 kA; at 690 V it is 4.25 kA."},{"question":"What compliance documentation does this brand provide for 3VA2116-5JQ32-0DL0?","answer":"As a SENTRON product, it carries the usual Siemens compliance declarations (RoHS, REACH, UL, IEC). Specific certificates are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-5JQ32-0DL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-5JQ32-0DL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}