{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-5KP32-0JL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-5KP32-0JL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-5KP32-0JL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5KP32-0JL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2116-5KP32-0JL0, 3-pole molded case circuit breaker, 160 A continuous, 187 kA at 240 V, line protection with communication function, shunt trip release.","salesMarkdown":"Siemens SENTRON 3VA2116-5KP32-0JL0 is a 3-pole molded case circuit breaker rated for 160 A continuous current with a maximum interrupting capacity of 187 kA at 240 VAC. Designed for line protection, it includes a shunt trip release and communication function for integration into automated systems. ## SCCR Headroom and Coordination The 187 kA SCCR at 240 V and 121 kA at 415 V give this breaker high fault-clearing capability for main or feeder panels where available fault current is substantial. At 690 V the rating drops to 3.7 kA, so for 690 V applications verify coordination with upstream devices. The 160 A continuous rating holds flat across 40 °C to 70 °C ambient — no derating needed in warm enclosures. Dimensions are 105 mm wide, 86 mm deep, 181 mm tall — fits standard MCCB panel cutouts. The 3-pole design with line-side and load-side lugs accepts copper or aluminum conductors. Auxiliary switch configuration includes 2 auxiliary switches plus 1 trip alarm and 1 electrical alarm switch (HQ type), providing status feedback for PLC or SCADA. Power loss is 25.5 W maximum at rated load.","metaTitle":"Siemens 3VA2116-5KP32-0JL0 SENTRON MCCB, 160 A, 3-Pole, 187","metaDescription":"Siemens SENTRON 3VA2116-5KP32-0JL0 molded case circuit breaker, 160 A continuous, 3-pole, 187 kA SCCR at 240 V. Line protection, communication function, shunt trip. Quoted to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 600 A","Minimum":"240 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"Yes","Of The Supplied Basic Switch":"3VA21165KP320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"160 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU850","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=98867&mlfb=3VA2116-5KP32-0JL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2116-5KP32-0JL0/alternatives.json"},"ai":{"faq":[{"question":"What is 3VA2116-5KP32-0JL0's depth?","answer":"Depth is 86 mm (3.39 in)."},{"question":"What is 3VA2116-5KP32-0JL0's width?","answer":"Width is 105 mm (4.13 in)."},{"question":"Where can I buy 3VA2116-5KP32-0JL0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation is available for 3VA2116-5KP32-0JL0?","answer":"As a Siemens SENTRON product, it is designed to meet applicable IEC and UL standards for molded case circuit breakers. Specific RoHS, REACH, UL, and IEC declarations are typically provided with the product documentation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-5KP32-0JL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-5KP32-0JL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}