{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-6HN32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-6HN32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-6HN32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-6HN32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, 3VA2116-6HN32-0AA0, 3-pole molded case circuit breaker, 160 A rated continuous current, ETU350 electronic trip unit, line protection design, interrupting ratings 242 kA at 240 V.","salesMarkdown":"## What the 160 A rating and ETU350 trip unit mean for your panel The 3VA2116-6HN32-0AA0 is a SENTRON 3VA2 molded case circuit breaker rated for 160 A continuous current at 40 °C through 70 °C — no derating needed across that ambient span, which simplifies panel layout in warm enclosures. ## Line protection design and integration into a 3-pole footprint The 3-pole format (105 mm wide, 181 mm tall, 86 mm deep) fits standard Siemens 3VA mounting accessories and busbar systems.","metaTitle":"Siemens 3VA2116-6HN32-0AA0 SENTRON MCCB, 160 A, 3-Pole, ETU3","metaDescription":"Siemens 3VA2116-6HN32-0AA0 SENTRON molded case circuit breaker, 160 A continuous, 3-pole, ETU350 electronic trip, 242 kA at 240 V. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 600 A","Minimum":"1 600 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"160 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=486160&mlfb=3VA2116-6HN32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2116-6HN32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What are the key interrupting ratings for 3VA2116-6HN32-0AA0?","answer":"242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. The steep drop at 690 V means you need to verify coordination if the breaker is applied on a 690 V line."},{"question":"Where can I buy 3VA2116-6HN32-0AA0?","answer":"Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for this order code."},{"question":"Does 3VA2116-6HN32-0AA0 require derating at high ambient temperatures?","answer":"No derating needed from 40 °C through 70 °C — the 160 A continuous rating holds across that entire ambient range, which simplifies panel thermal design."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-6HN32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-6HN32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}