{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-6JQ32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-6JQ32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-6JQ32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-6JQ32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2116-6JQ32-0AA0, molded case circuit breaker, 3-pole, 160 A continuous, line protection, 242 kA at 240 V, 187 kA at 415 V, 121 kA at 500 V, 3.7 kA at 690 V, 105 x 181 x 86 mm.","salesMarkdown":"The Siemens SENTRON 3VA2116-6JQ32-0AA0 is a 3-pole molded case circuit breaker rated for 160 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. The interrupting capacity tells the real story: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, then drops to 3.7 kA at 690 V. The 105 mm width fits a three-pole MCCB cutout in most distribution boards; check the gland plate clearance for the 86 mm depth, especially in shallow enclosures. Communication function is built in, so it can report status or trip events to a PLC or BMS without an add-on module.","metaTitle":"Siemens 3VA2116-6JQ32-0AA0 SENTRON MCCB, 160 A, 242 kA at 24","metaDescription":"Siemens SENTRON 3VA2116-6JQ32-0AA0 molded case circuit breaker, 160 A continuous, 242 kA at 240 V. Current production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 600 A","Minimum":"240 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Initial Value":"32 A","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Full-Scale Value":"160 A","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Summation current formation L-conductor","Continuous Current / Rated Value":"160 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU560","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Product Function / Grounding Protection":"Yes","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSIG","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=12941&mlfb=3VA2116-6JQ32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2116-6JQ32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for 3VA2116-6JQ32-0AA0?","answer":"Continuous current 160 A, 3-pole, interrupting capacity 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, 3.7 kA at 690 V. Rated insulation voltage 800 V. Dimensions 105 x 181 x 86 mm."},{"question":"Where can I buy 3VA2116-6JQ32-0AA0 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is listed here."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-6JQ32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-6JQ32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}