{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2116-8HN32-0KG0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2116-8HN32-0KG0","canonicalUrl":"https://aoctrl.com/siemens/3VA2116-8HN32-0KG0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2116-8HN32-0KG0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA2 IEC frame 160, class L, 3-pole, line protection ETU350 LSI, In=160 A, Icu=150 kA @ 415 V, shunt trip left 208-277 V AC, 1 auxiliary contact.","salesMarkdown":"## What this breaker is The Siemens 3VA2116-8HN32-0KG0 is a 3-pole IEC molded-case circuit breaker from the 3VA2 series, frame size 160, with a breaking capacity class L rated at Icu=150 kA at 415 V AC. Overload protection Ir is adjustable from 63 A to 160 A; short-circuit protection Isd ranges from 1.5 to 10 × Ir, and the instantaneous pickup Ii is fixed at 10 × In. This listing includes a factory-installed shunt trip on the left side, rated 208–277 V AC 50/60 Hz and 220–250 V DC, plus one auxiliary contact. The nut keeper kit is also included for secure mounting. The ETU350 electronic trip unit gives adjustable LSI curves, which is essential for selective coordination in a distribution panel: you can set the short-time delay (Isd) to ride through downstream faults and only trip on a sustained fault within its own zone. The 160 A frame with Ir down to 63 A means one physical breaker covers a wide range of load sizes — useful for BOM consolidation. The shunt trip on the left side allows remote tripping from an emergency-stop circuit or a fire-alarm relay. The auxiliary contact provides a status signal back to the PLC or DCS for fault annunciation.","metaTitle":"Siemens 3VA2116-8HN32-0KG0 Circuit Breaker, 160 A, 150 kA @","metaDescription":"Siemens 3VA2 IEC frame 160, class L, 150 kA @ 415 V, 3-pole, ETU350 LSI, 160 A, shunt trip left 208-277 V AC. Current lifecycle stage. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/83eff65c44469ff46b70582785c85926.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1438505&mlfb=3VA2116-8HN32-0KG0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2116-8HN32-0KG0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this breaker?","answer":"The ultimate breaking capacity Icu is 150 kA at 415 V AC, placing it in IEC class L for high-fault-current applications."},{"question":"What accessories are included with this order code?","answer":"This listing includes a factory-installed shunt trip on the left side (208–277 V AC 50/60 Hz, 220–250 V DC), one auxiliary contact, and a nut keeper kit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2116-8HN32-0KG0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2116-8HN32-0KG0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}