{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-5HL36-0DL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-5HL36-0DL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-5HL36-0DL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-5HL36-0DL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 molded case circuit breaker, 3-pole, 63 A rated continuous current, 187 kA breaking capacity at 240 V AC, line protection design with undervoltage release and auxiliary switches.","salesMarkdown":"The Siemens 3VA2163-5HL36-0DL0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for 63 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Breaking capacity hits 187 kA at 240 V AC, dropping to 121 kA at 415/440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. The UVR drops the breaker if control voltage falls below the dropout threshold — common in emergency-stop circuits or undervoltage protection schemes. The trip alarm gives a discrete signal when the breaker trips on fault, not just when manually opened. ## Integration notes The 3-pole body fits standard Siemens SENTRON 3VA2 mounting accessories — busbar kits, rear terminals, and door-coupling rotary handles share the same frame as other 3VA2 63 A variants. The auxiliary switch set (2 + 1 trip + 1 electrical alarm) occupies the left-side accessory slot; the undervoltage release fits the right-side slot.","metaTitle":"Siemens 3VA2163-5HL36-0DL0 SENTRON MCCB, 63 A, 187 kA at 240","metaDescription":"Siemens 3VA2163-5HL36-0DL0 SENTRON 3-pole MCCB, 63 A continuous, 187 kA breaking at 240 V. Active production, sourced to order. Request quote for volume pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"756 A","Minimum":"95 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"6.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21635HL360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=200239&mlfb=3VA2163-5HL36-0DL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2163-5HL36-0DL0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2163-5HL36-0DL0 at 240 V?","answer":"187 kA at 240 V AC. At 415 V and 440 V it is 121 kA, at 500 V it is 75.6 kA, and at 690 V it drops to 3.7 kA."},{"question":"Will 3VA2163-5HL36-0DL0 drop into a panel specified around 3VA2116-5HL32-0AK0?","answer":"Both are 3-pole SENTRON 3VA2 frame MCCBs sharing the same 105 mm width and 181 mm height. The 3VA2116-5HL32-0AK0 is a 16 A unit; the 3VA2163-5HL36-0DL0 is a 63 A unit. Panel cutout and mounting accessories are identical — no rewiring of the mounting footprint needed, but the busbar and cable sizing must match the higher 63 A rating."},{"question":"Where can I buy 3VA2163-5HL36-0DL0 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-5HL36-0DL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-5HL36-0DL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}