{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-5HN32-0HA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-5HN32-0HA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-5HN32-0HA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-5HN32-0HA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2163-5HN32-0HA0, molded case circuit breaker, 63 A continuous, 187 kA interrupting at 240 V, 3-pole, line protection, shunt trip (STL).","salesMarkdown":"That's unusual for an MCCB; many competitors start dropping current above 40 °C. The 800 V rated insulation voltage tells you the internal clearances and creepage are designed for 690 V systems, so it's safe on 400/480/690 V line-to-line circuits. The shunt trip (STL) is factory-installed on this variant, so you don't have to order a separate accessory and wire it in the field — one less thing to carry on the van. The basic switch module is order code 3VA21635HN320AA0, which is the replaceable core if the breaker ever needs internal service. Depth of 86 mm means it clears most standard enclosure backplates without hitting the door or gland plate. If you're swapping a failed 3VA2163-5HL32-0DB0 (a similar SENTRON variant), the physical footprint is identical — no rewiring needed, just match the trip curve and accessories.","metaTitle":"Siemens 3VA2163-5HN32-0HA0 SENTRON MCCB, 63 A, 187 kA at 240","metaDescription":"Siemens SENTRON 3VA2163-5HN32-0HA0 molded case circuit breaker, 63 A continuous, 187 kA interrupting at 240 V. Line protection, shunt trip, 3-pole. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"756 A","Minimum":"756 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"4 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21635HN320AA0","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=330215&mlfb=3VA2163-5HN32-0HA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2163-5HN32-0HA0/alternatives.json"},"ai":{"faq":[{"question":"Will 3VA2163-5HN32-0HA0 drop into a panel that was specified around 3VA2163-5HL32-0DB0 without rewiring?","answer":"Yes — both are 3-pole SENTRON 3VA2-frame MCCBs with identical physical dimensions (181 x 105 x 86 mm). The panel cutout and bus-bar connections are the same; the difference is in the trip unit and accessories. Verify the trip curve and shunt trip compatibility before ordering, but the mechanical fit is a direct swap."},{"question":"What is 3VA2163-5HN32-0HA0's listed depth (86 mm) on this component line?","answer":"The depth is 86 mm (3.39 in). That's the front-to-back dimension of the breaker body, not including the handle or any protruding terminals."},{"question":"What is 3VA2163-5HN32-0HA0's listed width (105 mm) on this component line?","answer":"The width is 105 mm (4.13 in). This is the standard 3-pole MCCB width for the SENTRON 3VA2 frame."},{"question":"Where can I buy 3VA2163-5HN32-0HA0 and what is the lead time?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-5HN32-0HA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-5HN32-0HA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}