{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-5JP46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-5JP46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-5JP46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-5JP46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2163-5JP46-0AA0, molded case circuit breaker, 4-pole, 63 A continuous, ETU550 electronic trip unit, line protection design, with communication function.","salesMarkdown":"## SENTRON 3VA2163-5JP46-0AA0 — 63 A MCCB with ETU550 Trip Unit The Siemens SENTRON 3VA2163-5JP46-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated for 63 A continuous current, fitted with the ETU550 electronic trip unit for line protection duty. It carries a breaking capacity of 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — high-interrupt ratings that suit it for main feeder or large subfeed applications where fault currents are substantial. The ETU550 electronic trip unit supports adjustable long-time pickup, short-time pickup, instantaneous, and ground-fault protection (though this variant ships without ground-fault monitoring). The 63 A frame is thermally stable across the full operating range: the continuous rating holds at ambient temperatures from 40 °C through 70 °C without derating, which simplifies panel sizing in warm environments. The breaker measures 181 mm high, 140 mm wide, and 86 mm deep — a standard SENTRON 3VA2 frame footprint. It mounts via screw terminals onto a backplate or into a compatible SENTRON distribution panel. Operating temperature range is -25 °C to 70 °C; storage range extends from -40 °C to 80 °C.","metaTitle":"Siemens 3VA2163-5JP46-0AA0 SENTRON MCCB, 63 A, 4-Pole, ETU55","metaDescription":"Siemens SENTRON 3VA2163-5JP46-0AA0 molded case circuit breaker, 63 A continuous, 4-pole, ETU550 electronic trip unit. Breaking capacity 187 kA at 240 V. Active production. Sourced","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"181 mm","Maximum":"756 A","Minimum":"95 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"5.51 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"4","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"4 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU550","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 40% to 160%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=155898&mlfb=3VA2163-5JP46-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2163-5JP46-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2163-5JP46-0AA0 at 415 V?","answer":"The breaking capacity is 121 kA at 415 V. At 240 V it is 187 kA, at 500 V it is 75.6 kA, and at 690 V it is 3.7 kA."},{"question":"What trip unit does this MCCB use?","answer":"It uses the ETU550 electronic trip unit, which provides adjustable protection settings and supports communication integration."},{"question":"Where can I buy 3VA2163-5JP46-0AA0 and get current pricing?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability confirmation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-5JP46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-5JP46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}