{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-5KP32-0HL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-5KP32-0HL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-5KP32-0HL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-5KP32-0HL0","rawCanonicalId":null},"summary":{"shortDescription":"SENTRON 3VA2163-5KP32-0HL0, 3-pole molded case circuit breaker, 63 A, interrupting capacity 187 kA at 240 V, line protection, ETU850 release, with communication & measurement functions.","salesMarkdown":"## Interrupting capacity and coordination The 79 kA at 500 V and 4.25 kA at 690 V cover the voltage bands common in 690 V mining or marine distribution. The 20 000 latching-endurance cycles support frequent switching in process lines. At 55 °C it holds 60.6 A, at 60 °C 58.3 A, at 65 °C 55.9 A, and at 70 °C 53.6 A — usable in a hot panel if you size the load accordingly. That width matches the standard 3-pole MCCB footprint on most DIN-rail adapter plates. The max power loss of 4 W at rated current keeps internal cabinet temperature rise manageable. ## Auxiliary and trip accessories","metaTitle":"SENTRON 3VA2163-5KP32-0HL0 3-Pole MCCB, 63 A, 187 kA at 240","metaDescription":"SENTRON 3VA2163-5KP32-0HL0 molded case circuit breaker, 3-pole, 63 A, interrupting capacity 187 kA at 240 V. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"4.25 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"60.6375 A","at 60 °C":"58.275 A","at 65 °C":"55.9125 A","at 70 °C":"53.55 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"Yes","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"4 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"Yes","Rated continuous current Iu":"63 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2163-5KP32-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL30","Design of the overcurrent release":"ETU850","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"25","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"63 A","Adjustable response value current / li max.":"756 A","Adjustable response value current / li min.":"95 A","Adjustable response value current / lr min.":"25 A","Adjustable response value current / Isd max.":"630 A","Adjustable response value current / Isd min.":"38 A","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"4","Protective function of the overcurrent release":"LSI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=29834&mlfb=3VA2163-5KP32-0HL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2163-5KP32-0HL0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2163-5KP32-0HL0?","answer":"This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing."},{"question":"What is the closest functional second-source for 3VA2163-5KP32-0HL0?","answer":"The closest functional peer is the 3VA1110-5EE32-0JA0. Both are 3-pole SENTRON MCCBs with electronic trip units, but the 3VA2163 carries higher interrupting capacity (187 kA vs the 3VA1110's lower rating) and includes communication and measurement functions as standard. The 3VA2163 will not drop into a panel wired for the 3VA1110 without verifying the breaker mounting footprint and bus bar spacing."},{"question":"What compliance documentation is available for 3VA2163-5KP32-0HL0?","answer":"As a SENTRON product, it carries the expected IEC/EN 60947-2 certifications. RoHS and REACH declarations are available from the manufacturer. Specific UL/CSA listing status should be confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-5KP32-0HL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-5KP32-0HL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}