{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-5MN36-0CL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-5MN36-0CL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-5MN36-0CL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-5MN36-0CL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2163-5MN36-0CL0, molded case circuit breaker, 3-pole, 63 A at 40 °C, breaking capacity 187 kA at 240 V, motor protection design with undervoltage release.","salesMarkdown":"Rated 63 A continuously across the full 40 °C to 70 °C ambient range — no derating needed up to that ceiling — it handles the sustained current of a motor branch circuit without nuisance tripping. Breaking capacity is where this unit separates itself: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. ## Motor protection and auxiliary configuration This MCCB ships with the basic switch 3VA21635MN360AA0 and comes factory-fitted with an undervoltage release (UVR) and an auxiliary switch block: 2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ. The UVR drops the breaker on loss of control voltage — standard for motor starters that need to prevent auto-restart after a power dip. Ground-fault monitoring is not included — this is a straight motor-protection MCCB, not a GFCI device. Dimensions are 181 mm high, 105 mm wide, 86 mm deep — a standard SENTRON 3VA frame size that mounts on a DIN rail or directly to a backplate. Operating temperature range is -25 °C to 70 °C, storage from -40 °C to 80 °C. Maximum power loss is 6.5 W, so panel thermal calculations are straightforward.","metaTitle":"Siemens 3VA2163-5MN36-0CL0 SENTRON MCCB, 63 A, 187 kA at 240","metaDescription":"Siemens SENTRON 3VA2163-5MN36-0CL0 molded case circuit breaker, 63 A rated, 187 kA breaking at 240 V. Motor protection design with undervoltage release. Active lifecycle, sourced t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"17 s","Minimum":"4 s","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"3.7 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Motor protection","Communication Function":"No","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"6.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21635MN360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10E, 20E","Design Of The Overcurrent Release":"ETU350M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"18 500 W","operating power / at AC-3 / at 400 V":"30 000 W","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB24","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"E","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569579&mlfb=3VA2163-5MN36-0CL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2163-5MN36-0CL0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2163-5MN36-0CL0 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity."},{"question":"What are the key ratings for 3VA2163-5MN36-0CL0?","answer":"Rated 63 A continuous at 40 °C to 70 °C ambient. Breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V. Three poles, motor protection design with phase failure detection and undervoltage release."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-5MN36-0CL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-5MN36-0CL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}