{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-6HL32-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-6HL32-0BA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-6HL32-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-6HL32-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2163-6HL32-0BA0, molded case circuit breaker, 3-pole, 63 A rated continuous current, 242 kA breaking capacity at 240 V AC, undervoltage release, ETU320 trip unit.","salesMarkdown":"## Siemens 3VA2163-6HL32-0BA0 — 63 A MCCB with Undervoltage Release The Siemens SENTRON 3VA2163-6HL32-0BA0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current at 40 °C, with a line-protection ETU320 trip unit. Its interrupting capacity reaches 242 kA at 240 V AC, 187 kA at 415 V, and 5 kA at 690 V — figures that govern selectivity and SCCR coordination in a distribution panel. No auxiliary contacts or communication module are fitted on this variant. Above that, derating applies: 60.6375 A at 55 °C, 58.275 A at 60 °C, 55.9125 A at 65 °C, and 53.55 A at 70 °C. Dimensions: 181 mm height, 105 mm width, 86 mm depth. The 3-pole footprint fits standard Siemens SENTRON mounting bases and busbar systems in distribution panels. The undervoltage release wiring terminates at the integrated trip block.","metaTitle":"Siemens 3VA2163-6HL32-0BA0 SENTRON MCCB, 63 A, 242 kA at 240","metaDescription":"Siemens SENTRON 3VA2163-6HL32-0BA0 molded case circuit breaker, 63 A rated, 242 kA breaking at 240 V. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","title":"3VA2163-6HL32-0BA0","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"5 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"60.6375 A","at 60 °C":"58.275 A","at 65 °C":"55.9125 A","at 70 °C":"53.55 A","description":"circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=63A overload protection Ir=25A...63A short-circuit protection Ii=1.5...12 x In nut keeper kit undervoltage release (UVR) 24V DC","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"6.5 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"63 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2163-6HL32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB11","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"63 A","Adjustable response value current / li max.":"756 A","Adjustable response value current / li min.":"95 A","Adjustable response value current / lr min.":"25 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=78921&mlfb=3VA2163-6HL32-0BA0"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2163-6HL32-0BA0 at 240 V?","answer":"242 kA at 240 V AC, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 5 kA at 690 V."},{"question":"Where can I buy 3VA2163-6HL32-0BA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does Siemens provide for this MCCB?","answer":"Siemens SENTRON MCCBs typically carry UL, CSA, CE, and IEC certifications, with RoHS and REACH declarations available on request. Specific approvals for this variant should be confirmed at order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-6HL32-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-6HL32-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}