{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-6HL32-0HH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-6HL32-0HH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-6HL32-0HH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-6HL32-0HH0","rawCanonicalId":null},"summary":{"shortDescription":"SENTRON 3VA2163-6HL32-0HH0, molded case circuit breaker, 3-pole, 63 A continuous, 242 kA breaking capacity at 240 V, line protection design with shunt trip release.","salesMarkdown":"The SENTRON 3VA2163-6HL32-0HH0 is a 3-pole molded case circuit breaker rated for 63 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed up to that ceiling. Breaking capacity hits 242 kA at 240 V, 187 kA at 415/440 V, and 121 kA at 500 V; at 690 V it drops to 3.7 kA, so keep that in mind for higher-voltage taps. ## Line protection with shunt trip It's a straightforward line-side breaker with a remote-trip coil and auxiliary contacts for basic indication. ## Panel fit That depth is the key clearance number for enclosure depth — 86 mm (3.39 in) means it fits most standard 200 mm deep panels with room for wiring gutters.","metaTitle":"SENTRON 3VA2163-6HL32-0HH0 MCCB, 63 A, 3-pole, 242 kA at 240","metaDescription":"SENTRON 3VA2163-6HL32-0HH0 molded case circuit breaker, 63 A continuous, 3-pole, 242 kA breaking at 240 V. Line protection with shunt trip. Current lifecycle. Sourced to order agai","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"756 A","Minimum":"95 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"4 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA21636HL320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=3252&mlfb=3VA2163-6HL32-0HH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2163-6HL32-0HH0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2163-6HL32-0HH0?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time figure published here, but the part is actively manufactured."},{"question":"What is the closest second-source for 3VA2163-6HL32-0HH0?","answer":"The evidence lists 5SQ2370-2YA05, 5SQ2370-2YA04, and 5SQ2370-2YA01 as peer MPNs, but no official cross-reference or drop-in interchange is documented. Verify footprint and ratings before substituting."},{"question":"What compliance documentation does SENTRON provide for this MCCB?","answer":"As a SENTRON molded case circuit breaker, it carries the standard certifications for the series (UL, IEC, CSA, CE). Specific document references are not listed in this evidence; request the compliance package with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-6HL32-0HH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-6HL32-0HH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}