{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-6HL36-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-6HL36-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-6HL36-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-6HL36-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2163-6HL36-0DA0, 3-pole molded case circuit breaker, 63 A continuous, line protection, undervoltage release, 242 kA at 240 V.","salesMarkdown":"The Siemens SENTRON 3VA2163-6HL36-0DA0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current across its full operating temperature range from -25 °C to 70 °C. The interrupting ratings are substantial: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. That kind of high-fault capacity means this breaker can sit close to the transformer or service entrance without worrying about cascading failure upstream. That's unusual; most MCCBs start shedding current above 40 °C. If your panel runs hot, this breaker doesn't force a larger frame size. The adjustable thermal-magnetic trip (the 95 A minimum to 756 A maximum range on the magnetic pickup) lets you fine-tune the short-circuit protection to the load without swapping the breaker body. The 3VA2163-6HL36-0DA0 measures 105 mm wide, 181 mm high, and 86 mm deep — that's a 4.13 x 7.13 x 3.39 inch footprint. The 3-pole design fits standard 3-phase distribution panels; the UVR adds a small coil draw but no extra width.","metaTitle":"Siemens 3VA2163-6HL36-0DA0 SENTRON MCCB, 63 A, 3-Pole, UVR","metaDescription":"Siemens SENTRON 3VA2163-6HL36-0DA0 molded case circuit breaker, 63 A continuous, 3-pole, line protection, with undervoltage release. Breaking capacity 242 kA at 240 V. Current life","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"756 A","Minimum":"95 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"6.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2163-6HL36-0AA0","Design Of The Auxiliary Switch":"Without","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=167654&mlfb=3VA2163-6HL36-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2163-6HL36-0DA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2163-6HL36-0DA0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the breaking capacity of 3VA2163-6HL36-0DA0 at different voltages?","answer":"The interrupting ratings are 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V."},{"question":"Does 3VA2163-6HL36-0DA0 include an undervoltage release?","answer":"Yes, it comes with a factory-installed undervoltage release (UVR) as indicated by the -0DA0 suffix."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-6HL36-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-6HL36-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}