{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-6HL36-0JA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-6HL36-0JA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-6HL36-0JA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-6HL36-0JA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2163-6HL36-0JA0, molded case circuit breaker, 3-pole, 63 A rated continuous current Iu, line protection version with ETU320 overcurrent release, breaking capacity 242 kA at 240 V.","salesMarkdown":"The Siemens SENTRON 3VA2163-6HL36-0JA0 is a 3-pole molded case circuit breaker rated for 63 A continuous current (Iu) in a line protection configuration. The breaker is dimensioned at 105 mm wide, 181 mm tall, and 86 mm deep, fitting standard SENTRON panel cutouts and busbar systems. This MCCB delivers 242 kA at 240 V, 187 kA at both 415 V and 440 V, 121 kA at 500 V, and 5 kA at 690 V. For a 63 A frame, 242 kA at 240 V is exceptionally high, which means you can place this breaker close to a large transformer or generator bus without worrying about the fault current exceeding its rating. At 690 V the capacity drops to 5 kA, so if you're on a 690 V line, verify that the prospective fault current stays under that threshold or coordinate with an upstream current-limiting device. The breaker holds full 63 A rating from 40 °C up to 50 °C ambient. At 55 °C it derates to 60.6 A, at 60 °C to 58.3 A, at 65 °C to 55.9 A, and at 70 °C to 53.6 A. Operating ambient range is -25 °C to 70 °C, storage range -40 °C to 80 °C. Maximum power loss is 4 W.","metaTitle":"Siemens 3VA2163-6HL36-0JA0 SENTRON MCCB, 63 A, 3-Pole, 242 k","metaDescription":"Siemens SENTRON 3VA2163-6HL36-0JA0 molded case circuit breaker, 63 A continuous, 3-pole, line protection with ETU320 release. Breaking capacity 242 kA at 240 V. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"5 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"60.6375 A","at 60 °C":"58.275 A","at 65 °C":"55.9125 A","at 70 °C":"53.55 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"4 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"63 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2163-6HL36-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL32","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"63 A","Adjustable response value current / li max.":"756 A","Adjustable response value current / li min.":"95 A","Adjustable response value current / lr min.":"25 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (6-120 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=29193&mlfb=3VA2163-6HL36-0JA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2163-6HL36-0JA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2163-6HL36-0JA0 and how is it quoted?","answer":"This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here."},{"question":"What is the depth of 3VA2163-6HL36-0JA0?","answer":"The listed depth is 86 mm."},{"question":"What is the width of 3VA2163-6HL36-0JA0?","answer":"The listed width is 105 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-6HL36-0JA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-6HL36-0JA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}