{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-6HN32-0AG0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-6HN32-0AG0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-6HN32-0AG0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-6HN32-0AG0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2163-6HN32-0AG0, molded case circuit breaker, 3-pole, 63 A rated continuous current, 242 kA interrupting capacity at 240 V, line protection design.","salesMarkdown":"The Siemens SENTRON 3VA2163-6HN32-0AG0 is a 3-pole molded case circuit breaker rated for 63 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Its interrupting capacity of 242 kA at 240 V (187 kA at 415 V, 121 kA at 500 V, 3.7 kA at 690 V) means it can safely clear a fault of that magnitude without upstream cascading, which is the figure that governs your SCCR coordination study. The breaker occupies 105 mm width, 181 mm height, and 86 mm depth — standard SENTRON 3VA footprint for a 3-pole frame. It mounts directly into a switchboard or enclosure busbar system; the auxiliary switch and trip alarm are factory-integrated, so no separate wiring of add-on blocks is needed for basic status feedback.","metaTitle":"Siemens 3VA2163-6HN32-0AG0 SENTRON MCCB, 63 A, 242 kA at 240","metaDescription":"Siemens SENTRON 3VA2163-6HN32-0AG0 molded case circuit breaker, 63 A rated, 242 kA interrupting at 240 V, 3-pole, line protection. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"756 A","Minimum":"756 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"4 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2163-6HN32-0AA0","Design Of The Auxiliary Switch":"1 auxiliary switch + 1 trip alarm switch HP","Design Of The Auxiliary Release":"Without auxiliary release","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB11","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1248&mlfb=3VA2163-6HN32-0AG0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2163-6HN32-0AG0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2163-6HN32-0AG0 and what is the lead time?","answer":"We source and quote this breaker to order against an RFQ. Availability and current pricing are confirmed at quote time through our independent distribution channels."},{"question":"What is the interrupting capacity of 3VA2163-6HN32-0AG0 at 240 V?","answer":"242 kA at 240 V. At 415 V it is 187 kA, at 500 V it is 121 kA, and at 690 V it is 3.7 kA."},{"question":"Does 3VA2163-6HN32-0AG0 include auxiliary contacts?","answer":"Yes, it ships with one auxiliary switch and one trip alarm switch (HP type), factory-fitted."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-6HN32-0AG0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-6HN32-0AG0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}