{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-6HN36-0DL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-6HN36-0DL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-6HN36-0DL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-6HN36-0DL0","rawCanonicalId":null},"summary":{"shortDescription":"SENTRON 3VA2163-6HN36-0DL0 molded case circuit breaker, 3-pole, 63 A rated current, 242 kA breaking capacity at 240 V, line protection, undervoltage release, 105 mm width, 86 mm depth, 181 mm height.","salesMarkdown":"The 3VA2163-6HN36-0DL0 is a SENTRON molded case circuit breaker rated for 63 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed up to 70 °C, which simplifies panel design for hot environments like enclosed MCCs or outdoor cabinets. Its 242 kA breaking capacity at 240 V and 187 kA at 415 V cover high-fault scenarios near large transformers or busways; at 690 V the rating drops to 3.7 kA, so verify the available fault current on 690 V systems before specifying. The 3-pole design with undervoltage release (UVR) means it trips on loss of control voltage, a standard safety feature for motor branch circuits and emergency-stop chains. The built-in trip indicator and the auxiliary switch configuration (2 aux + 1 trip alarm + 1 electrical alarm) reduce external wiring for status feedback to the PLC or SCADA.","metaTitle":"SENTRON 3VA2163-6HN36-0DL0 MCCB, 63 A, 242 kA at 240 V","metaDescription":"SENTRON 3VA2163-6HN36-0DL0 molded case circuit breaker, 63 A rated current, 242 kA breaking at 240 V, 3-pole, line protection, undervoltage release, current production, sourced to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"756 A","Minimum":"756 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"3.7 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"6.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2163-6HN36-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=375554&mlfb=3VA2163-6HN36-0DL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2163-6HN36-0DL0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2163-6HN36-0DL0 at different voltages?","answer":"242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V."},{"question":"Where can I buy 3VA2163-6HN36-0DL0?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-6HN36-0DL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-6HN36-0DL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}