{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-7MN32-0CA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-7MN32-0CA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-7MN32-0CA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-7MN32-0CA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON, molded case circuit breaker, 3VA2163-7MN32-0CA0, 3-pole, 63 A at 40 °C, motor protection design, 330 kA at 240 V, undervoltage release.","salesMarkdown":"Breaking capacity is 330 kA at 240 V, dropping to 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. ## Current rating across temperature That simplifies panel design in warm enclosures; you don't need to oversize the breaker for a 55 °C switchroom. The width — 105 mm — is the critical dimension for a multi-breaker lineup; verify your backpanel layout fits the 3-pole width.","metaTitle":"Siemens 3VA2163-7MN32-0CA0 SENTRON MCCB, 63 A, 3-Pole, Motor","metaDescription":"Siemens SENTRON molded case circuit breaker, 63 A, 3-pole, motor protection design with undervoltage release. 330 kA breaking at 240 V. Active production. Sourced to order against","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"17 s","Minimum":"4 s","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"3.7 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Motor protection","Communication Function":"No","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"6.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2163-7MN32-0AA0","Design Of The Auxiliary Switch":"Without","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10E, 20E","Design Of The Overcurrent Release":"ETU350M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"18 500 W","operating power / at AC-3 / at 400 V":"30 000 W","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB24","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569687&mlfb=3VA2163-7MN32-0CA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2163-7MN32-0CA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2163-7MN32-0CA0?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time; the breaker is sourced to order through independent distribution."},{"question":"What is 3VA2163-7MN32-0CA0's listed depth?","answer":"86 mm (3.39 in)."},{"question":"What is 3VA2163-7MN32-0CA0's listed width?","answer":"105 mm (4.13 in)."},{"question":"What compliance documentation does this brand provide for 3VA2163-7MN32-0CA0?","answer":"The SENTRON series carries IEC 60947-2 certification for molded case circuit breakers. Specific RoHS, REACH, and UL documentation should be requested at quote time from the supplier — the evidence does not list individual certificates."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-7MN32-0CA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-7MN32-0CA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}