{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-7MN36-0DL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-7MN36-0DL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-7MN36-0DL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-7MN36-0DL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2163-7MN36-0DL0, molded case circuit breaker, 3-pole, 63 A, motor protection version, ETU350M release, 330 kA at 240 V, with undervoltage release and auxiliary contacts.","salesMarkdown":"## What this MCCB does on a motor circuit It carries a continuous current of 63 A at 40 °C and delivers a 330 kA interrupting capacity at 240 V, which drops to 242 kA at 415 V and 440 V, then to 187 kA at 500 V, and 52.5 kA at 690 V. That interrupting curve means it can handle high-fault scenarios on a 480 V distribution bus without cascading upstream — a solid fit for a motor control center feeding pumps or conveyors. An undervoltage release (UVR) is fitted as standard, so the breaker drops out if line voltage sags below the release threshold. That is useful on machines that must auto-stop on a brownout rather than restart unexpectedly. Maximum power loss is 75 W at rated current. ## Thermal derating and ambient range Above that it derates: 60.48 A at 55 °C, 59.22 A at 60 °C, 57.96 A at 65 °C, and 56.7 A at 70 °C.","metaTitle":"Siemens 3VA2163-7MN36-0DL0 SENTRON MCCB, 63 A, 330 kA at 240","metaDescription":"Siemens 3VA2163-7MN36-0DL0 SENTRON molded case circuit breaker, 63 A rated, 330 kA at 240 V interrupting capacity. Motor protection with ETU350M release, undervoltage release, phas","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"52.5 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"60.48 A","at 60 °C":"59.22 A","at 65 °C":"57.96 A","at 70 °C":"56.7 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Motor protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"75 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"63 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2163-7MN36-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"ETU350M","Protection class IP / on the front":"IP40","Operating power / at AC-3 / at 400 V":"22 W","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"4","Adjustable response value time / tsd max.":"0.03 s","Adjustable response value time / tsd min.":"0.03 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"63 A","Adjustable response value current / li max.":"945 A","Adjustable response value current / li min.":"945 A","Adjustable response value current / lr min.":"25 A","Adjustable response value current / Isd max.":"945 A","Adjustable response value current / Isd min.":"189 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"4","Protective function of the overcurrent release":"LSI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching capacity class of the circuit breaker":"C","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569727&mlfb=3VA2163-7MN36-0DL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2163-7MN36-0DL0/alternatives.json"},"ai":{"faq":[{"question":"Will 3VA2163-7MN36-0DL0 drop into a panel specified around 3VA2163-8HM32-0AA0?","answer":"Both are 3-pole SENTRON 3VA2 frame breakers with the same 105 mm width, 181 mm height, and 86 mm depth. The physical footprint is identical — no rewiring of the bus bars or DIN-rail position is needed. The difference is in the trip unit and accessories: the -8HM32-0AA0 variant carries a different electronic release and auxiliary contact configuration, so verify the protection settings match your application."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-7MN36-0DL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-7MN36-0DL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}