{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2163-8JQ46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2163-8JQ46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2163-8JQ46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2163-8JQ46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"SENTRON 3VA2163-8JQ46-0AA0, molded case circuit breaker, 4-pole, 63 A rated continuous current, line protection design, breaking capacity 440 kA at 240 V.","salesMarkdown":"## MCCB for line protection — 63 A, 4-pole, 440 kA interrupting capacity The interrupting capacity climbs to 440 kA at 240 V, dropping to 330 kA at 415 V and 440 V, 220 kA at 500 V, and 52.5 kA at 690 V — a curve that tells you this breaker is built for high-fault locations like transformer secondaries or main feeders where available fault current is substantial. The 3.1 W maximum power loss is modest for a 63 A frame; panel ventilation requirements stay minimal. ## Ground-fault and communication provisions This variant includes ground-fault monitoring via summation current formation on L + N conductors — it sums the phase and neutral currents to detect leakage. A communication function is built in, which means it can interface with a higher-level monitoring system for remote trip indication or load management. No undervoltage release or voltage trip is fitted; this is a straight overcurrent + ground-fault device.","metaTitle":"SENTRON 3VA2163-8JQ46-0AA0 MCCB, 63 A, 4-Pole, 440 kA at 240","metaDescription":"SENTRON 3VA2163-8JQ46-0AA0 molded case circuit breaker, 63 A rated, 4-pole, line protection. Breaking capacity 440 kA at 240 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"140 mm","title":"3VA2163-8JQ46-0AA0","Height":"181 mm","Maximum":"756 A","Minimum":"95 A","at 240 V":"440 kA","at 415 V":"330 kA","at 440 V":"330 kA","at 500 V":"220 kA","at 690 V":"52.5 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"63 A","at 60 °C":"63 A","at 65 °C":"63 A","at 70 °C":"63 A","Depth [In]":"3.39 in","Width [In]":"5.51 in","Height [In]":"7.13 in","description":"circuit breaker 3VA2 IEC frame 160 breaking capacity class L Icu=150kA @ 415V 4-pole, line protection ETU560, LSIG, In=63A overload protection Ir=25A...63A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection adjustable (OFF, up to 160%) gr.-fault prot., can be sw. off Ig=0.25...1 x In= tg=0.05-0.8s clamp connection","Initial Value":"16 A","Trip Indicator":"No","Number Of Poles":"4","Voltage Trigger":"No","lifecycle_stage":"current","Full-Scale Value":"63 A","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"3.1 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Summation current formation L + N conductor","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU560","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 40% to 160%","Product Function / Grounding Protection":"Yes","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSIG","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"L","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"double-sided box terminal","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b27f8f8fa25a6619d6d76a928fe2e8a2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=3981&mlfb=3VA2163-8JQ46-0AA0"},"ai":{"faq":[{"question":"Where can I buy 3VA2163-8JQ46-0AA0 and get current pricing?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of this MCCB at different voltages?","answer":"440 kA at 240 V, 330 kA at 415 V and 440 V, 220 kA at 500 V, and 52.5 kA at 690 V."},{"question":"Does this breaker include ground-fault protection?","answer":"Yes, it includes ground-fault monitoring via summation current formation on L + N conductors."},{"question":"What is the depth of 3VA2163-8JQ46-0AA0?","answer":"86 mm — the dimension to check against enclosure door clearance or busbar shroud depth."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2163-8JQ46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2163-8JQ46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}