{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2216-5MN32-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2216-5MN32-0BA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2216-5MN32-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2216-5MN32-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2216-5MN32-0BA0 molded case circuit breaker, 3-pole, 160 A rated continuous current at 40 °C, motor protection version with ETU350M electronic trip unit, undervoltage release, phase failure detection.","salesMarkdown":"The Siemens 3VA2216-5MN32-0BA0 is a SENTRON molded case circuit breaker (MCCB) in the motor protection version, rated for 160 A continuous current at 40 °C and carrying a 187 kA interrupting capacity at 240 V. Three-pole design, 160 A frame. The interrupting capacity drops as voltage climbs: 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 17 kA at 690 V. It also includes an undervoltage release (UVR), so if your control voltage drops, the breaker opens — no separate undervoltage relay needed. The depth of 86 mm leaves room for rear-connected busbars or cable lugs in a typical 600 mm deep enclosure. ## Environment and approvals That 70 °C top end means it can sit next to a hot motor starter or transformer without derating the frame — though the ETU350M trip curve may need a second look at elevated temps. Maximum power loss is 75 W. No auxiliary contacts or ground-fault monitoring built in; those are add-on modules. The breaker carries the SENTRON brand, which typically holds UL 489, CSA C22.2 No. 5, and IEC 60947-2 certifications — verify the specific listing for your jurisdiction at quote time.","metaTitle":"Siemens 3VA2216-5MN32-0BA0 SENTRON MCCB, 160 A, 3-Pole, Moto","metaDescription":"Siemens 3VA2216-5MN32-0BA0 SENTRON molded case circuit breaker, 160 A rated continuous current at 40 °C, 3-pole, motor protection with ETU350M release, undervoltage release, phase","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","title":"3VA2216-5MN32-0BA0","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"17 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"153.6 A","at 60 °C":"150.4 A","at 65 °C":"147.2 A","at 70 °C":"144 A","description":"circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=160A overload protection Ir=63A...160A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 24V DC","Trip indicator":"No","Number of poles":"3","Product version":"Motor protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"75 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"160 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2216-5MN32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB11","Design of the overcurrent release":"ETU350M","Protection class IP / on the front":"IP40","Operating power / at AC-3 / at 400 V":"55 W","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"17","Adjustable response value time / tr min.":"4","Adjustable response value time / tsd max.":"0.03 s","Adjustable response value time / tsd min.":"0.03 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"160 A","Adjustable response value current / li max.":"2 400 A","Adjustable response value current / li min.":"2 400 A","Adjustable response value current / lr min.":"63 A","Adjustable response value current / Isd max.":"2 400 A","Adjustable response value current / Isd min.":"480 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LSI","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"250 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/925896f022f1bf1dfe799568fd778a5f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569823&mlfb=3VA2216-5MN32-0BA0"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2216-5MN32-0BA0?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels — no stock count or price is published here."},{"question":"What are the key specifications of 3VA2216-5MN32-0BA0?","answer":"160 A rated continuous current at 40 °C, 3 poles, motor protection version with ETU350M electronic trip unit, 187 kA interrupting capacity at 240 V, 121 kA at 415 V, 75.6 kA at 500 V, 17 kA at 690 V. Includes undervoltage release and phase failure detection. Dimensions: 181 mm high, 105 mm wide, 86 mm deep."},{"question":"What compliance documentation is available for 3VA2216-5MN32-0BA0?","answer":"As a SENTRON product, this MCCB typically carries UL 489, CSA C22.2 No. 5, and IEC 60947-2 certifications, plus RoHS and REACH compliance. Specific declaration numbers are confirmed at quote time against the exact production lot."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2216-5MN32-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2216-5MN32-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}