{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2216-5MN32-0DL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2216-5MN32-0DL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2216-5MN32-0DL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2216-5MN32-0DL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2216-5MN32-0DL0, molded case circuit breaker (MCCB), 3-pole, 160 A, motor protection design, 121 kA at 415 V, with undervoltage release and auxiliary switches.","salesMarkdown":"## Breaking capacity — what it clears and where Breaking capacity is the real gate for panel coordination. At 240 V it's rated 187 kA; at 500 V it drops to 75.6 kA; at 690 V it's 4.5 kA. The short-time withstand and trip indicator help with selective coordination studies. ## Integrated protection and signaling That means a loss of control voltage drops the breaker open, which is standard for safety circuits on conveyors or pumps where an unexpected restart after a power dip is unacceptable. Phase failure detection is also integrated, so a lost phase on the line side trips the breaker rather than letting the motor single-phase and overheat.","metaTitle":"Siemens 3VA2216-5MN32-0DL0 SENTRON MCCB, 160 A, 3-Pole, Moto","metaDescription":"Siemens 3VA2216-5MN32-0DL0 SENTRON molded case circuit breaker, 160 A, 3-pole, motor protection design with undervoltage release. Breaking capacity 121 kA at 415 V. Active producti","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"17 s","Minimum":"4 s","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"4.5 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Motor protection","Communication Function":"No","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"22.2 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2216-5MN32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"160 A","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10E, 20E","Design Of The Overcurrent Release":"ETU350M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"45 000 W","operating power / at AC-3 / at 400 V":"75 000 W","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"250 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/925896f022f1bf1dfe799568fd778a5f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569834&mlfb=3VA2216-5MN32-0DL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2216-5MN32-0DL0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2216-5MN32-0DL0 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent industrial distribution. Availability and current pricing are confirmed at quote time — submit an RFQ with quantity and target delivery window."},{"question":"What is the breaking capacity of 3VA2216-5MN32-0DL0 at 415 V?","answer":"At 415 V the breaking capacity is 121 kA. At 240 V it is 187 kA, at 500 V it is 75.6 kA, and at 690 V it is 4.5 kA."},{"question":"What compliance documentation does this brand provide for 3VA2216-5MN32-0DL0?","answer":"As a Siemens SENTRON product, this MCCB is designed to meet IEC 60947-2 and UL 489 standards. RoHS and REACH declarations are available from Siemens documentation. The evidence does not list specific cert numbers, but the brand and product class imply CE, UKCA, and EAC marking for the relevant markets."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2216-5MN32-0DL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2216-5MN32-0DL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}