{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2216-5MP32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2216-5MP32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2216-5MP32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2216-5MP32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2216-5MP32-0AA0, molded case circuit breaker, 3-pole, 160 A, motor protection with ETU550M trip unit.","salesMarkdown":"Siemens 3VA2216-5MP32-0AA0 is a SENTRON molded case circuit breaker for motor protection — 160 A continuous, 3-pole, with an ETU550M electronic trip unit supporting adjustable trip classes 10A, 10/10E, 20/20E, and 30. Rated breaking capacity hits 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 4.5 kA at 690 V. ## Motor protection trip unit The ETU550M is a microprocessor-based overcurrent release with phase failure detection and communication capability. Adjustable trip class lets you match the thermal curve to motor start profiles — class 10A for fast starts (short stall time), class 30 for high-inertia loads like centrifuges or crushers.","metaTitle":"Siemens 3VA2216-5MP32-0AA0 SENTRON MCCB, 160 A, 3-pole, ETU5","metaDescription":"Siemens SENTRON 3VA2216-5MP32-0AA0 molded case circuit breaker, 160 A, 3-pole, motor protection, ETU550M trip unit. Active production. Available to order — request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"4.5 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Product version":"Motor protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"Yes","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"19.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"160 A","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10/10E, 20/ 20E, 30","Design Of The Overcurrent Release":"ETU550M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"45 000 W","operating power / at AC-3 / at 400 V":"75 000 W","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"250 A","Product Extension / Optional / Motor Drive":"Yes","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Switching Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8 mm","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/925896f022f1bf1dfe799568fd778a5f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1133446&mlfb=3VA2216-5MP32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2216-5MP32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Will 3VA2216-5MP32-0AA0 drop into a panel designed for 3VA2116-5JP32-0AE0?","answer":"Yes — same frame size (3VA2 platform), same 160 A rating, same 3-pole footprint. Physical fit is identical; check the trip unit wiring if the old panel used auxiliary contacts or communication cabling specific to the ETU550M."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2216-5MP32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2216-5MP32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}