{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2216-5MP32-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2216-5MP32-0AB0","canonicalUrl":"https://aoctrl.com/siemens/3VA2216-5MP32-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2216-5MP32-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2216-5MP32-0AB0, 160 A rated, 3-pole, 187 kA at 240 V, 86 mm depth, 105 mm width, 181 mm height.","salesMarkdown":"Three poles, with a breaking capacity of 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 4.5 kA at 690 V. That kind of headroom makes it a main or large-feeder breaker in a panel where fault current is high and selectivity with downstream 3VA1 or 3VA2 breakers matters. Rated insulation voltage 800 V. Communication function and phase failure detection are built in — no external module needed for basic status monitoring or phase-loss trip. ## Mounting and integration — panel footprint Bolts into a standard MCCB cutout on a panel backplate or into a SENTRON mounting plate. The 3-pole form factor matches existing 3VA2 busbar and lug kits. 19.7 W max power loss at rated load — factor that into enclosure ventilation if the panel is sealed. ## Auxiliaries and release options — what ships on the breaker Trip indicator is not fitted (visual flag absent). If you need shunt trip, UVR, or ground-fault add-on, those are separate order codes that plug into the accessory slot.","metaTitle":"Siemens 3VA2216-5MP32-0AB0 SENTRON MCCB, 160 A, 3-Pole, 187","metaDescription":"Siemens 3VA2216-5MP32-0AB0 SENTRON molded case circuit breaker, 160 A rated, 3-pole, 187 kA breaking at 240 V. Current lifecycle stage. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"20 s","Minimum":"3 s","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"4.5 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"Yes","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"19.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"#BEZUG!","Design Of The Auxiliary Switch":"2 auxiliary switches HP","Design Of The Auxiliary Release":"Without auxiliary release","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10/10E, 20/ 20E, 30","Design Of The Overcurrent Release":"ETU550M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"45 000 W","operating power / at AC-3 / at 400 V":"75 000 W","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA11","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/925896f022f1bf1dfe799568fd778a5f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1472757&mlfb=3VA2216-5MP32-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2216-5MP32-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2216-5MP32-0AB0 at different voltages?","answer":"187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 4.5 kA at 690 V."},{"question":"Does the 3VA2216-5MP32-0AB0 include a trip indicator or undervoltage release?","answer":"No trip indicator and no undervoltage release are fitted as standard. The breaker ships with 2 HP auxiliary switches only."},{"question":"Where can I buy 3VA2216-5MP32-0AB0 and what is the lead time?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2216-5MP32-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2216-5MP32-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}