{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2216-7HM32-0AC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2216-7HM32-0AC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2216-7HM32-0AC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2216-7HM32-0AC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA2 IEC frame 250 MCCB, 3-pole, breaking capacity class C, Icu=110kA @ 415V, ETU330 electronic trip unit with LIG protection, In=160A, includes nut keeper kit and 2 auxiliary switch changeover H.","salesMarkdown":"The Siemens 3VA2216-7HM32-0AC0 is a 3-pole IEC frame 250 molded case circuit breaker rated for line protection with an Icu of 110 kA at 415 V — that's breaking capacity class C, meaning it clears high fault currents without cascading upstream, which matters when you're coordinating a distribution board or feeding a motor control center. The ETU330 electronic trip unit gives you LIG protection: overload (L) adjustable Ir=63A to 160A, short-circuit (I) adjustable Ii=1.5 to 12 x In, and ground-fault (G) adjustable Ig=0.2 to 1 x In with time delay tg=0.1 or 0.3 s. That ground-fault element is what sets this apart from a plain thermal-magnetic — it catches low-level arcing faults a thermal trip might miss, which on a conveyor line or pump panel saves you from a burned-out motor winding or a fire risk. The auxiliary contacts report breaker status back to the PLC or status lamp without extra wiring.","metaTitle":"Siemens 3VA2216-7HM32-0AC0 Circuit Breaker, 110kA @ 415V","metaDescription":"Siemens 3VA2216-7HM32-0AC0 IEC frame 250 MCCB, 3-pole, ETU330 LIG, In=160A, Icu=110kA @ 415V. Active lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/925896f022f1bf1dfe799568fd778a5f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1420142&mlfb=3VA2216-7HM32-0AC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2216-7HM32-0AC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2216-7HM32-0AC0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is 3VA2216-7HM32-0AC0's listed description and key ratings?","answer":"It is a Siemens 3VA2 IEC frame 250 MCCB, 3-pole, breaking capacity class C, Icu=110kA @ 415V, with an ETU330 electronic trip unit providing LIG protection (overload, short-circuit, ground-fault), rated In=160A with adjustable Ir=63A...160A, Ii=1.5...12 x In, Ig=0.2...1 x In, tg=0.1/0.3s. Includes nut keeper kit and 2 auxiliary switch changeover H."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2216-7HM32-0AC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2216-7HM32-0AC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}