{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2216-7KP32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2216-7KP32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2216-7KP32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2216-7KP32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2216-7KP32-0AA0, molded case circuit breaker, 3-pole, 160 A continuous, ETU850 electronic release, line protection, 330 kA interrupting at 240 V, IP40 front, communication function.","salesMarkdown":"Its interrupting capacity hits 330 kA at 240 V and still holds 242 kA at 415 V or 440 V — that's the kind of fault-clearing muscle you need for high-available-current transformer secondaries or large motor control centers where a weak breaker would cascade upstream. That simplifies panel layout: you don't have to oversize the frame or add forced ventilation just because the breaker sits next to other heat sources. The maximum power loss is 19.7 W, so heat dissipation is manageable even in a sealed enclosure. ## Physical fit and mounting","metaTitle":"Siemens 3VA2216-7KP32-0AA0 SENTRON MCCB, 160 A, 3-Pole, 330","metaDescription":"Siemens 3VA2216-7KP32-0AA0 SENTRON molded case circuit breaker, 160 A continuous, 3-pole, 330 kA at 240 V. ETU850 release, communication capable. Active production, sourced to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"1 920 A","Minimum":"240 A","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"4.5 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"19.7 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"Yes","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"160 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU850","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"250 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/925896f022f1bf1dfe799568fd778a5f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=211732&mlfb=3VA2216-7KP32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2216-7KP32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2216-7KP32-0AA0 and how do I get a price?","answer":"We source this breaker to order against an RFQ. Submit a request through our quoting system; availability and current pricing are confirmed at quote time."},{"question":"What is 3VA2216-7KP32-0AA0's listed depth (86 mm) on this component line?","answer":"The depth is 86 mm (3.39 in). That's the dimension from the mounting surface to the furthest projection on the back — important for shallow enclosures or when you need clearance behind the panel."},{"question":"What is 3VA2216-7KP32-0AA0's listed width (105 mm) on this component line?","answer":"The width is 105 mm (4.13 in). This is standard for a 3-pole MCCB frame, so it will fit existing cutouts and DIN-rail spacing designed for that footprint."},{"question":"What compliance documentation does this brand provide for 3VA2216-7KP32-0AA0 (RoHS, REACH, UL, IEC)?","answer":"As a Siemens SENTRON product, the breaker carries the usual CE marking and is designed to IEC 60947-2. RoHS and REACH declarations are available from Siemens — check their support portal for the specific declaration of conformity for this order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2216-7KP32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2216-7KP32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}