{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2216-7MQ32-0AG0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2216-7MQ32-0AG0","canonicalUrl":"https://aoctrl.com/siemens/3VA2216-7MQ32-0AG0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2216-7MQ32-0AG0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2216-7MQ32-0AG0, molded case circuit breaker, 3-pole, 160 A, motor protection version, ETU860M release, 330 kA at 240 V.","salesMarkdown":"At 240 V it interrupts 330 kA; at 415 V and 440 V it holds 242 kA, dropping to 4.5 kA at 690 V — the SCCR headroom covers most industrial service-entrance and feeder applications where high fault current is expected. Communication function is onboard, and the breaker supports integration into a higher-level automation system for remote trip indication and load management. The 3VA2216-7MQ32-0AG0 measures 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint for DIN-rail or screw-mount panel integration.","metaTitle":"Siemens 3VA2216-7MQ32-0AG0 SENTRON MCCB, 160 A, 330 kA at 24","metaDescription":"Siemens SENTRON 3VA2216-7MQ32-0AG0 molded case circuit breaker, 160 A, 330 kA at 240 V, 3-pole, motor protection, ETU860M release, current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"4.5 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"160 A","at 60 °C":"160 A","at 65 °C":"160 A","at 70 °C":"160 A","Width [in]":"4.1 in","Height [in]":"7.1 in","Number of poles":"3","Product version":"Motor protection","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Communication Function":"Yes","Phase failure detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"20 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"Yes","Rated continuous current Iu":"160 A","Rated insulation voltage Ui":"800 V","Ground fault monitoring version":"Summation current formation L-conductor","Design of the overcurrent release":"ETU860M","Protection class IP / on the front":"IP40","Operating power / at AC-3 / at 230 V":"45 000 W","Operating power / at AC-3 / at 400 V":"75 000 W","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"20","Adjustable response value time / tr min.":"3","Adjustable response value time / tsd max.":"0 s","Adjustable response value time / tsd min.":"0 s","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"160 A","Adjustable response value current / lg max.":"160 A","Adjustable response value current / lg min.":"32 A","Adjustable response value current / li max.":"2 400 A","Adjustable response value current / li min.":"480 A","Adjustable response value current / lr min.":"64 A","Adjustable response value current / tg max.":"0.8 s","Adjustable response value current / tg min.":"0.05 s","Adjustable response value current / Isd max.":"2 400 A","Adjustable response value current / Isd min.":"192 A","Ground fault protection can be switched ON/OFF":"Yes","Neutral conductors / upgradeable/retrofittable":"No","Protective function of the overcurrent release":"LSIG","Switching capacity class of the circuit breaker":"C","Max. rated operational current of the frame size":"250 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/925896f022f1bf1dfe799568fd778a5f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1124600&mlfb=3VA2216-7MQ32-0AG0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2216-7MQ32-0AG0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting rating of 3VA2216-7MQ32-0AG0 at 240 V?","answer":"At 240 V the breaker interrupts 330 kA. At 415 V and 440 V it interrupts 242 kA, and at 500 V it interrupts 187 kA. At 690 V the rating drops to 4.5 kA."},{"question":"Where can I buy 3VA2216-7MQ32-0AG0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial response."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2216-7MQ32-0AG0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2216-7MQ32-0AG0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}