{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2220-5MN32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2220-5MN32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2220-5MN32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2220-5MN32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, 3VA2220-5MN32-0AA0, molded case circuit breaker (MCCB), motor protection design, 3-pole, 200 A rated current, adjustable trip class 10A/10E/20E, 800 V insulation voltage.","salesMarkdown":"Three poles, adjustable trip class (10A, 10E, 20E), and phase failure detection are on board. ## Short-circuit ratings that follow the voltage The interrupting capacity drops as the line voltage rises — 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 5.2 kA at 690 V. That 121 kA at 415 V is the figure that matters for most European industrial panels; the 5.2 kA at 690 V means this frame is not the right choice for a 690 V bus unless the fault level is very low. ## Motor protection trip classes Adjustable trip class gives you 10A (fast — tight thermal protection for short-time overloads), 10E (standard motor start), or 20E (high-inertia loads like fans or centrifuges that need a longer acceleration ramp). The 200 A frame covers motor FLC from roughly 100 A up to the 200 A ceiling, depending on the OL setting range. ## Panel fit Footprint is 105 mm wide × 181 mm high × 86 mm deep — standard 3-pole MCCB envelope for a 200 A frame.","metaTitle":"Siemens 3VA2220-5MN32-0AA0 SENTRON MCCB, 200 A, 3-Pole","metaDescription":"Siemens 3VA2220-5MN32-0AA0 SENTRON molded case circuit breaker, 200 A rated, 3-pole, motor protection design. SCCR 187 kA at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"15 s","Minimum":"4 s","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"5.2 kA","at 40 °C":"200 A","at 45 °C":"200 A","at 50 °C":"200 A","at 55 °C":"200 A","at 60 °C":"200 A","at 65 °C":"200 A","at 70 °C":"200 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Motor protection","Communication Function":"No","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"46 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"200 A","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10E, 20E","Design Of The Overcurrent Release":"ETU350M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"37 000 W","operating power / at AC-3 / at 400 V":"75 000 W","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"250 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$447.04","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569078&mlfb=3VA2220-5MN32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2220-5MN32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2220-5MN32-0AA0?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."},{"question":"What is the interrupting capacity of this MCCB at 415 V?","answer":"121 kA at 415 V — the same figure applies at 440 V. At 240 V it rises to 187 kA."},{"question":"What trip classes are available on 3VA2220-5MN32-0AA0?","answer":"Adjustable between 10A, 10E, and 20E. Pick 10A for fast thermal protection, 10E for standard motor starts, or 20E for high-inertia loads."},{"question":"Does this MCCB include phase failure detection?","answer":"Yes, phase failure detection is built in — standard for the motor protection variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2220-5MN32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2220-5MN32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}