{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2220-5MN32-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2220-5MN32-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2220-5MN32-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2220-5MN32-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, molded case circuit breaker (MCCB), 3VA2220-5MN32-0DA0, 3-pole, 200 A rated continuous current, motor protection version with ETU350M electronic overcurrent release, 187 kA breaking capacity at 240 V.","salesMarkdown":"## What this MCCB does for a motor branch It carries an ETU350M electronic overcurrent release with phase failure detection built in, so it handles the inrush and running protection of a 200 A motor branch without needing a separate relay. Above that it steps down: 192 A at 55 °C, 188 A at 60 °C, 184 A at 65 °C, 180 A at 70 °C. This MCCB's interrupting rating drops as voltage rises, which is typical for air-break designs. At 240 V it's 187 kA, at 415 V and 440 V it's 121 kA, at 500 V it's 75.6 kA, and at 690 V it's 17 kA. For a 400 V distribution panel the 121 kA figure gives solid headroom over typical 50-65 kA SCCR requirements. At 690 V the 17 kA limit means it's not a primary feeder breaker for high-fault 690 V systems — that's a coordination point to check. Dimensions are 105 mm wide, 181 mm high, 86 mm deep — a standard 3-pole MCCB footprint for the 3VA2 frame size. No auxiliary contact version is fitted as standard, so if you need status feedback, that's an add-on. Maximum power loss is 75 W at rated load — account for that heat in a sealed enclosure.","metaTitle":"Siemens SENTRON 3VA2220-5MN32-0DA0 MCCB, 200 A, 3-Pole, Moto","metaDescription":"Siemens SENTRON 3VA2220-5MN32-0DA0 molded case circuit breaker, 200 A rated, 3-pole, motor protection version with ETU350M release. Breaking capacity 187 kA at 240 V. Current lifec","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","title":"3VA2220-5MN32-0DA0","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"17 kA","at 40 °C":"200 A","at 45 °C":"200 A","at 50 °C":"200 A","at 55 °C":"192 A","at 60 °C":"188 A","at 65 °C":"184 A","at 70 °C":"180 A","description":"circuit breaker 3VA2 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, motor protection ETU350M, LSI, In=200A overload protection Ir=80A...200A short-circuit protection Isd=3...15 x Ir, Ii=15 x In nut keeper kit undervoltage release (UVR) 208-230V AC 50/60Hz","Trip indicator":"No","Number of poles":"3","Product version":"Motor protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"75 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"200 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2220-5MN32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"ETU350M","Protection class IP / on the front":"IP40","Operating power / at AC-3 / at 400 V":"75 W","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"15","Adjustable response value time / tr min.":"4","Adjustable response value time / tsd max.":"0.03 s","Adjustable response value time / tsd min.":"0.03 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"200 A","Adjustable response value current / li max.":"3 000 A","Adjustable response value current / li min.":"3 000 A","Adjustable response value current / lr min.":"80 A","Adjustable response value current / Isd max.":"3 000 A","Adjustable response value current / Isd min.":"600 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LSI","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"250 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=570085&mlfb=3VA2220-5MN32-0DA0"},"ai":{"faq":[{"question":"Where can I buy 3VA2220-5MN32-0DA0 and how do I get a price?","answer":"This MCCB is sourced and quoted to order against an RFQ through independent industrial distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time on your quantity."},{"question":"What are the key ratings of 3VA2220-5MN32-0DA0?","answer":"Rated continuous current 200 A, 3-pole, motor protection version with ETU350M electronic overcurrent release and phase failure detection. Breaking capacity is 187 kA at 240 V, 121 kA at 415 V, 121 kA at 440 V, 75.6 kA at 500 V, and 17 kA at 690 V. Rated insulation voltage is 800 V."},{"question":"What is the depth of 3VA2220-5MN32-0DA0?","answer":"The depth is 86 mm. Overall dimensions are 105 mm wide by 181 mm high by 86 mm deep."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2220-5MN32-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2220-5MN32-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}