{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2220-7MN32-0DC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2220-7MN32-0DC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2220-7MN32-0DC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2220-7MN32-0DC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2220-7MN32-0DC0, molded case circuit breaker, 3-pole, 200 A, motor protection version with ETU350M electronic trip unit, 330 kA at 240 V, 86 x 105 x 181 mm.","salesMarkdown":"## Motor protection MCCB with ETU350M — 200 A frame It carries the ETU350M electronic trip unit with phase failure detection, so it catches a lost phase before the motor winding takes damage — that's the difference between a thermal-magnetic and this electronic curve. Breaking capacity lands at 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 52.5 kA at 690 V — high enough for most industrial main and sub-feed applications without cascading upstream breakers. Rated continuous current holds at 200 A from 40 °C through 50 °C, then steps down: 192 A at 55 °C, 188 A at 60 °C, 184 A at 65 °C, 180 A at 70 °C. That's a 10 % drop at the top of the range — factor it into the enclosure's internal ambient, not the room temperature. Maximum power loss is 75 W. That's the dissipation at full rated current through the main poles plus the electronic trip — relevant for heat buildup in a sealed enclosure. The integrated undervoltage release (UVR) and 2 auxiliary switches (HQ type) are factory-fitted; no field assembly required. Dimensions are 86 mm depth, 105 mm width, 181 mm height. That's the standard 3VA2 frame footprint — mounts on a mounting plate or DIN rail via the adapter. The 3-pole width of 105 mm matches the 3VA2 200 A frame; if the existing panel was cut for a 3VA1 frame, the width is the same, so no re-punching needed.","metaTitle":"Siemens 3VA2220-7MN32-0DC0 SENTRON MCCB, 200 A, 3-pole, Moto","metaDescription":"Siemens 3VA2220-7MN32-0DC0 SENTRON molded case circuit breaker, 200 A rated continuous current, 3-pole motor protection, ETU350M electronic trip, 330 kA at 240 V. Current productio","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"52.5 kA","at 40 °C":"200 A","at 45 °C":"200 A","at 50 °C":"200 A","at 55 °C":"192 A","at 60 °C":"188 A","at 65 °C":"184 A","at 70 °C":"180 A","Trip indicator":"No","Number of poles":"3","Product version":"Motor protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"75 W","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"200 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2220-7MN32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"ETU350M","Protection class IP / on the front":"IP40","Operating power / at AC-3 / at 400 V":"75 W","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"15","Adjustable response value time / tr min.":"4","Adjustable response value time / tsd max.":"0.03 s","Adjustable response value time / tsd min.":"0.03 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"200 A","Adjustable response value current / li max.":"3 000 A","Adjustable response value current / li min.":"3 000 A","Adjustable response value current / lr min.":"80 A","Adjustable response value current / Isd max.":"3 000 A","Adjustable response value current / Isd min.":"600 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LSI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"C","Max. rated operational current of the frame size":"250 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569935&mlfb=3VA2220-7MN32-0DC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2220-7MN32-0DC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2220-7MN32-0DC0 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time, not a published list price."},{"question":"What is 3VA2220-7MN32-0DC0's listed depth?","answer":"The depth is 86 mm, width 105 mm, height 181 mm — standard 3VA2 200 A frame dimensions."},{"question":"Will 3VA2220-7MN32-0DC0 drop into a panel specified around 3VA1112-5EF32-0CA0 without rewiring?","answer":"Both are 3-pole SENTRON MCCBs on the same frame width (105 mm for the 200 A frame), so the mounting footprint is compatible. However, the 3VA1112-5EF32-0CA0 is a different frame size (160 A max) with a thermal-magnetic trip; the 3VA2220-7MN32-0DC0 uses an ETU350M electronic trip with different wiring for the undervoltage release and auxiliary contacts — verify the control circuit termination before swapping."},{"question":"What compliance documentation does this brand provide for 3VA2220-7MN32-0DC0?","answer":"Siemens SENTRON MCCBs carry IEC 60947-2 certification as standard. RoHS and REACH declarations are included with the product documentation. UL/CSA listings vary by specific variant — confirm the exact UL file number when the application requires it."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2220-7MN32-0DC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2220-7MN32-0DC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}