{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2220-7MN32-0JC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2220-7MN32-0JC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2220-7MN32-0JC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2220-7MN32-0JC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 series, molded case circuit breaker (MCCB), 3VA2220-7MN32-0JC0, 200 A, 3-pole, motor protection design, 330 kA interrupting capacity at 240 V.","salesMarkdown":"The 3-pole configuration with phase failure detection means it will trip on a lost phase before the motor single-phases and cooks the winding; that's the difference between a nuisance call and a rewind. Interrupting capacity is 330 kA at 240 V AC, dropping to 242 kA at 415 V and 440 V, then 187 kA at 500 V, and 5.2 kA at 690 V. That 330 kA figure at 240 V covers high-fault scenarios like a transformer secondary close to the service entrance; the 5.2 kA at 690 V is still adequate for most 690 V motor circuits but worth checking against your available fault current if you're on a high-capacity industrial grid. ## Fit and integration into the panel Physical envelope is 181 mm high by 105 mm wide by 86 mm deep. No undervoltage release fitted on this variant, so it won't drop out on a sag; that's correct for motor protection where you want the starter contactor to handle undervoltage, not the breaker. Maximum power dissipation is 46 W at rated current.","metaTitle":"Siemens 3VA2220-7MN32-0JC0 SENTRON MCCB, 200 A, 3-Pole, Moto","metaDescription":"Siemens SENTRON 3VA2220-7MN32-0JC0 molded case circuit breaker. 200 A continuous at 70 °C, 330 kA at 240 V interrupting capacity. Motor protection design with phase failure detecti","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"15 s","Minimum":"4 s","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"5.2 kA","at 40 °C":"200 A","at 45 °C":"200 A","at 50 °C":"200 A","at 55 °C":"200 A","at 60 °C":"200 A","at 65 °C":"200 A","at 70 °C":"200 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Motor protection","Communication Function":"No","Phase Failure Detection":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"46 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2220-7MN32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"200 A","Insulation Voltage / Rated Value":"800 V","adjustable trip class (Tc CLASS)":"10A, 10E, 20E","Design Of The Overcurrent Release":"ETU350M","protection class IP / on the front":"IP40","operating power / at AC-3 / at 230 V":"37 000 W","operating power / at AC-3 / at 400 V":"75 000 W","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"250 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569943&mlfb=3VA2220-7MN32-0JC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2220-7MN32-0JC0/alternatives.json"},"ai":{"faq":[{"question":"Does this breaker include a shunt trip or undervoltage release?","answer":"It includes a shunt trip release (STL) for remote tripping from a safety circuit or E-stop. It does NOT include an undervoltage release — that's correct for motor protection duty, where the contactor handles undervoltage and the breaker handles overcurrent and short-circuit protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2220-7MN32-0JC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2220-7MN32-0JC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}