{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2220-7MS32-0BH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2220-7MS32-0BH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2220-7MS32-0BH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2220-7MS32-0BH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2220-7MS32-0BH0, molded case circuit breaker, 3-pole, 200 A continuous, interrupting capacity 330 kA at 240 VAC, undervoltage release, 2 aux + 1 trip alarm switches.","salesMarkdown":"## SENTRON 3VA2220-7MS32-0BH0 — 200 A MCCB with undervoltage release The Siemens SENTRON 3VA2220-7MS32-0BH0 is a 3-pole molded case circuit breaker (MCCB) rated for 200 A continuous at 40 °C through 70 °C — no derating across that band, which simplifies panel thermal budgeting. Its interrupting capacity reaches 330 kA at 240 VAC and holds 242 kA at 415/440 VAC, then drops to 187 kA at 500 VAC and 5.2 kA at 690 VAC. That SCCR profile suits main or feeder duty in 480 V industrial distribution where fault current runs high. The base switch is order code 3VA2220-7MS32-0AA0. Built-in trip indicator and starter-protection design make it a fit for motor branch circuits where undervoltage drop-out is required by code or safety logic. Dimensions: 181 mm height, 105 mm width, 86 mm depth. The 3-pole frame occupies standard MCCB panel space; the 105 mm width matches the SENTRON 3VA2 three-pole footprint. Maximum power loss is 46 W — account for that in enclosed panel thermal calculations. For selective coordination studies, the trip indicator aids fault localization during commissioning and troubleshooting.","metaTitle":"Siemens 3VA2220-7MS32-0BH0 SENTRON MCCB, 200 A, 3-Pole, 330","metaDescription":"Siemens SENTRON 3VA2220-7MS32-0BH0 molded case circuit breaker, 200 A continuous, 3-pole, 330 kA IC at 240 VAC. Current production. Undervoltage release. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"3 000 A","Minimum":"600 A","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"5.2 kA","at 40 °C":"200 A","at 45 °C":"200 A","at 50 °C":"200 A","at 55 °C":"200 A","at 60 °C":"200 A","at 65 °C":"200 A","at 70 °C":"200 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Starter protection","Communication Function":"No","Phase Failure Detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"46 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2220-7MS32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"200 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU310M","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB11","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"250 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"I","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"C","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569960&mlfb=3VA2220-7MS32-0BH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2220-7MS32-0BH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2220-7MS32-0BH0 and how do I get a price?","answer":"This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote."},{"question":"What is 3VA2220-7MS32-0BH0's interrupting capacity at 240 V?","answer":"330 kA at 240 VAC. At 415 V and 440 V it is 242 kA, at 500 V it is 187 kA, and at 690 V it is 5.2 kA."},{"question":"Does the 3VA2220-7MS32-0BH0 include an undervoltage release?","answer":"Yes, it is fitted with an undervoltage release (UVR) as standard, plus 2 auxiliary switches and 1 trip alarm switch (HQ design)."},{"question":"What are the physical dimensions of this MCCB?","answer":"Height 181 mm, width 105 mm, depth 86 mm. The 105 mm width is the standard 3-pole SENTRON 3VA2 frame width."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2220-7MS32-0BH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2220-7MS32-0BH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}