{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2220-7MS32-0CC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2220-7MS32-0CC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2220-7MS32-0CC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2220-7MS32-0CC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2220-7MS32-0CC0, molded case circuit breaker, 3-pole, 200 A rated continuous current, 330 kA breaking capacity at 240 V, ETU310M electronic trip unit, undervoltage release, 2 HQ auxiliary switches.","salesMarkdown":"Rated breaking capacity drops from 330 kA at 240 V to 242 kA at 415 V and 440 V, then 187 kA at 500 V, and 52.5 kA at 690 V. For a 400 V distribution panel, the 242 kA figure still covers most high-fault installations; at 690 V the 52.5 kA rating suits industrial motor feeders with moderate fault levels. The 200 A rating holds up to 50 °C ambient. Above that, current must be derated: 192 A at 55 °C, 188 A at 60 °C, 184 A at 65 °C, and 180 A at 70 °C. If the panel runs hot — near a drive cabinet or in a non-climate-controlled enclosure — factor that into the load schedule. The maximum power loss is 75 W, which adds to the enclosure's thermal budget. ## Auxiliary and trip details The basic switch assembly is order code 3VA2220-7MS32-0AA0; the integrated auxiliary trip module is 3VA9608-0BB24. No voltage trigger, no communication function, no phase failure detection — this is a straightforward thermal-magnetic + electronic trip MCCB with UVR. ## Environmental and storage","metaTitle":"Siemens 3VA2220-7MS32-0CC0 SENTRON MCCB, 200 A, 330 kA at 24","metaDescription":"Siemens SENTRON 3VA2220-7MS32-0CC0 molded case circuit breaker, 200 A rated, 330 kA breaking at 240 V. 3-pole, ETU310M release, undervoltage trip. Active production. Order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"52.5 kA","at 40 °C":"200 A","at 45 °C":"200 A","at 50 °C":"200 A","at 55 °C":"192 A","at 60 °C":"188 A","at 65 °C":"184 A","at 70 °C":"180 A","Trip indicator":"No","Number of poles":"3","Product version":"Starter protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"75 W","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"200 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2220-7MS32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB24","Design of the overcurrent release":"ETU310M","Protection class IP / on the front":"IP40","Operating power / at AC-3 / at 400 V":"75 W","Reference code / acc. to DIN EN 81346-2":"Q","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"0 A","Adjustable response value current / li max.":"3 000 A","Adjustable response value current / li min.":"600 A","Adjustable response value current / lr min.":"0 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"I","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"C","Max. rated operational current of the frame size":"250 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=569963&mlfb=3VA2220-7MS32-0CC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2220-7MS32-0CC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2220-7MS32-0CC0 and how do I get a price?","answer":"We source this part to order against an RFQ. Send us your quantity and target delivery window; we'll confirm availability and current pricing at quote time."},{"question":"What are the key ratings of 3VA2220-7MS32-0CC0?","answer":"Rated continuous current 200 A, breaking capacity 330 kA at 240 V, 242 kA at 415/440 V, 187 kA at 500 V, 52.5 kA at 690 V. Insulation voltage 800 V. 3-pole, ETU310M electronic trip, undervoltage release, 2 HQ auxiliary switches."},{"question":"What compliance documentation does Siemens provide for this MCCB?","answer":"Standard Siemens SENTRON MCCBs carry IEC 60947-2 certification and UL 489 listing. RoHS and REACH declarations are available from Siemens documentation. Specific certificates for this order code can be requested with the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2220-7MS32-0CC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2220-7MS32-0CC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}