{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2225-5JP32-0DL0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2225-5JP32-0DL0","canonicalUrl":"https://aoctrl.com/siemens/3VA2225-5JP32-0DL0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2225-5JP32-0DL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2225-5JP32-0DL0, 250 A continuous, 3-pole, 187 kA at 240 V, line protection with undervoltage release and communication function.","salesMarkdown":"The Siemens 3VA2225-5JP32-0DL0 is a SENTRON molded case circuit breaker (MCCB) rated for 250 A continuous current, with an interrupting capacity of 187 kA at 240 V and 121 kA at 415 V. At 415 V it still handles 121 kA, dropping to 75.6 kA at 500 V and 4.5 kA at 690 V. That 690 V figure is low enough that you need to check coordination upstream if your system runs at that voltage. Above 55 °C it steps down: 238 A at 55 °C, 225 A at 60 °C, 213 A at 65 °C, 200 A at 70 °C. The communication function is built in, so no separate comm module is needed for basic monitoring. That 105 mm width is the standard 3-pole MCCB footprint for the 3VA2 frame size — it fits the same panel cutout and bus bar spacing as other 3VA2 3-pole units. The 86 mm depth includes the rear terminals; check your gland plate clearance if the panel is shallow. Power loss is rated at 50.5 W maximum at full load. That is moderate for a 250 A frame — plan for ventilation or derating if the breaker is packed tightly with other heat sources in a sealed enclosure.","metaTitle":"Siemens 3VA2225-5JP32-0DL0 SENTRON MCCB, 250 A, 187 kA at 24","metaDescription":"Siemens 3VA2225-5JP32-0DL0 SENTRON molded case circuit breaker, 250 A continuous, 187 kA at 240 V, 3-pole, undervoltage release, communication capable. Current production. Sourced","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"2 500 A","Minimum":"375 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"75.6 kA","at 690 V":"4.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"238 A","at 60 °C":"225 A","at 65 °C":"213 A","at 70 °C":"200 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"Yes","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"50.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2225-5JP32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU550","protection class IP / on the front":"IP40","design of the N-conductor protection":"adjustable OFF; 20% to 160%","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"250 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"4","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB22","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=245468&mlfb=3VA2225-5JP32-0DL0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2225-5JP32-0DL0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA2225-5JP32-0DL0?","answer":"Pricing and availability are confirmed at quote time against an RFQ. Submit a request through the storefront and you will get a current price and lead time for your quantity."},{"question":"What is the interrupting capacity of this MCCB at different voltages?","answer":"187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 4.5 kA at 690 V. The 690 V figure is the low point — verify coordination if your system runs at that voltage."},{"question":"What compliance documentation does this breaker have?","answer":"The SENTRON 3VA2 series is UL, CSA, and IEC certified. RoHS and REACH documentation is available from Siemens."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2225-5JP32-0DL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2225-5JP32-0DL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}