{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2225-5JP32-0KC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2225-5JP32-0KC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2225-5JP32-0KC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2225-5JP32-0KC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2 molded case circuit breaker, 3-pole, 250 A rated continuous current, 187 kA breaking capacity at 240 V, ETU550 electronic trip unit, shunt trip release, 2 auxiliary switches HQ, communication function.","salesMarkdown":"The Siemens 3VA2225-5JP32-0KC0 is a 3-pole SENTRON molded case circuit breaker rated for line protection at 250 A continuous current, holding that rating flat from 40 °C up to 50 °C before it starts to derate — at 55 °C it's 238 A, at 60 °C it's 225 A, at 65 °C it's 213 A, and at 70 °C it's 200 A. That means in a warm panel you lose headroom fast; if your load pulls 240 A and the enclosure sits at 55 °C, this breaker is already at its limit. Breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 5.1 kA at 690 V. At 690 V the 5.1 kA is modest; if your system runs 690 V with high fault current, this isn't the breaker for that bus. No undervoltage release, no phase-failure detection, no ground-fault monitoring module on this variant — those are separate add-on options. ## Panel fit — footprint and wiring In a multi-breaker lineup, factor that into the enclosure's thermal budget; a sealed stainless box with no fan will cook the trip unit electronics if you stack several of these at full load.","metaTitle":"Siemens 3VA2225-5JP32-0KC0 SENTRON MCCB, 250 A, 187 kA at 24","metaDescription":"Siemens 3VA2225-5JP32-0KC0 SENTRON molded case circuit breaker, 250 A rated, 187 kA breaking at 240 V. ETU550 trip unit, shunt trip, communication ready. Sourced to order against R","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"121 kA","at 500 V":"79 kA","at 690 V":"5.1 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"238 A","at 60 °C":"225 A","at 65 °C":"213 A","at 70 °C":"200 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"Yes","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"48 W","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"250 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2225-5JP32-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL33","Design of the overcurrent release":"ETU550","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"15","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"250 A","Adjustable response value current / li max.":"2 500 A","Adjustable response value current / li min.":"375 A","Adjustable response value current / lr min.":"100 A","Adjustable response value current / Isd max.":"2 500 A","Adjustable response value current / Isd min.":"150 A","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LSI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"250 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=396890&mlfb=3VA2225-5JP32-0KC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2225-5JP32-0KC0/alternatives.json"},"ai":{"faq":[{"question":"Will 3VA2225-5JP32-0KC0 drop into a panel wired for 3VA1110-5EE32-0JA0?","answer":"No — the 3VA2225 uses a larger frame (105 mm wide vs the 3VA1's narrower footprint), different busbar spacing, and a different accessory mounting scheme. The panel cutout and wiring need to be reworked."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2225-5JP32-0KC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2225-5JP32-0KC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}