{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2225-6HL32-0JH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2225-6HL32-0JH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2225-6HL32-0JH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2225-6HL32-0JH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2225-6HL32-0JH0, Molded case circuit breaker, Line protection, 3-pole, 250 A rated, 242 kA breaking capacity at 240 V, 187 kA at 415 V, 121 kA at 500 V.","salesMarkdown":"Its interrupting capacity hits 242 kA at 240 V and still holds 187 kA at 415 V — that's serious fault-clearing headroom for a 250 A frame. The 105 mm width and 181 mm height fit standard panel layouts; depth runs 86 mm. At 500 V it still delivers 121 kA; at 690 V it drops to 4.5 kA, so it's not a 690 V main breaker but handles downstream feeders at that voltage. Thermal derating is gradual: 250 A holds steady through 50 °C, then drops to 241 A at 55 °C and 213 A at 70 °C. That means in a hot panel (say 55 °C ambient), you lose only 9 A — still well within a 250 A load's margin. ## Built-in accessories and fit That saves panel-builder wiring time — no separate add-on modules to snap in. The base switch is order code 3VA2225-6HL32-0AA0; the -0JH0 suffix adds the shunt trip and aux switches.","metaTitle":"Siemens 3VA2225-6HL32-0JH0 SENTRON MCCB, 250A, 242kA at 240V","metaDescription":"Siemens SENTRON 3VA2225-6HL32-0JH0 molded case circuit breaker, 250A rated, 3-pole, 242kA breaking at 240V. Current production. Sourced to order. Request RFQ for pricing and availa","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"2 500 A","Minimum":"375 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"4.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"241 A","at 60 °C":"232 A","at 65 °C":"222 A","at 70 °C":"213 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"48 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2225-6HL32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"250 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=255810&mlfb=3VA2225-6HL32-0JH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2225-6HL32-0JH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2225-6HL32-0JH0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What are the key ratings for 3VA2225-6HL32-0JH0?","answer":"Rated continuous current 250 A at 40 °C, 3-pole, breaking capacity 242 kA at 240 V, 187 kA at 415 V, 121 kA at 500 V, 4.5 kA at 690 V. Dimensions: 105 mm wide, 181 mm tall, 86 mm deep."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2225-6HL32-0JH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2225-6HL32-0JH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}