{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2225-6HL32-0KH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2225-6HL32-0KH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2225-6HL32-0KH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2225-6HL32-0KH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2225-6HL32-0KH0, molded case circuit breaker, 3-pole, 250 A continuous, 242 kA at 240 V, 187 kA at 415/440 V, line protection design.","salesMarkdown":"## Siemens SENTRON 3VA2225-6HL32-0KH0 — 250 A MCCB, 3-Pole, Line Protection Its breaking capacity varies by system voltage: 242 kA at 240 VAC, 187 kA at 415 VAC and 440 VAC, 121 kA at 500 VAC, and 4.5 kA at 690 VAC — the 690 V figure is a steep drop, so verify your fault current at that voltage before specifying. The continuous current rating holds at 250 A from 40 °C through 50 °C ambient, then derates linearly to 213 A at 70 °C. A voltage trigger indicator is present; undervoltage release and ground-fault monitoring are not fitted on this order code. No communication function is built in — it is a standalone thermal-magnetic or electronic trip unit (the base switch is 3VA2225-6HL32-0AA0). Dimensions: 181 mm height, 105 mm width, 86 mm depth. At 105 mm wide, it occupies three standard 35 mm module spaces plus a small margin — confirm clearance against adjacent devices in a crowded enclosure.","metaTitle":"Siemens 3VA2225-6HL32-0KH0 SENTRON MCCB, 250 A, 3-Pole, 242","metaDescription":"Siemens SENTRON 3VA2225-6HL32-0KH0 molded case circuit breaker, 250 A continuous, 3-pole, 242 kA breaking capacity at 240 VAC. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"2 500 A","Minimum":"375 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"4.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"241 A","at 60 °C":"232 A","at 65 °C":"222 A","at 70 °C":"213 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"48 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2225-6HL32-0AA0","Design Of The Auxiliary Switch":"2 auxiliary switches + 1 trip alarm switch HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU320","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL33","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"250 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"3","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=402722&mlfb=3VA2225-6HL32-0KH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2225-6HL32-0KH0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA2225-6HL32-0KH0 at 415 V?","answer":"187 kA at 415 VAC. The same rating applies at 440 VAC. At 240 VAC it reaches 242 kA, at 500 VAC it drops to 121 kA, and at 690 VAC it is 4.5 kA."},{"question":"Where can I buy 3VA2225-6HL32-0KH0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2225-6HL32-0KH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2225-6HL32-0KH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}