{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2225-6HN32-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2225-6HN32-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA2225-6HN32-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2225-6HN32-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2225-6HN32-0DA0, molded case circuit breaker, 3-pole, 250 A rated continuous current, 242 kA breaking capacity at 240 V AC, undervoltage release, line protection design.","salesMarkdown":"The Siemens SENTRON 3VA2225-6HN32-0DA0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuous current at 40 °C, with a maximum breaking capacity of 242 kA at 240 V AC. This is a line-protection design, meaning it's intended for feeder or main breaker duty rather than motor protection — no ground-fault monitoring or communication function on this variant. The interrupting rating drops as voltage climbs: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 4.5 kA at 690 V. Continuous current holds at 250 A from 40 °C up to 50 °C, then derates linearly to 213 A at 70 °C. Maximum power loss is 50.5 W — account for that heat in a sealed enclosure.","metaTitle":"Siemens 3VA2225-6HN32-0DA0 SENTRON MCCB, 250 A, 3-Pole, 242","metaDescription":"Siemens 3VA2225-6HN32-0DA0 SENTRON molded case circuit breaker, 250 A continuous, 3-pole, 242 kA at 240 V. Active production. Available to order; RFQ for current pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","Maximum":"2 500 A","Minimum":"2 500 A","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"4.5 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"241 A","at 60 °C":"232 A","at 65 °C":"222 A","at 70 °C":"213 A","Depth [In]":"3.39 in","Width [In]":"4.13 in","Height [In]":"7.13 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"50.5 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA2225-6HN32-0AA0","Design Of The Auxiliary Switch":"Without","Design Of The Auxiliary Release":"undervoltage release (UVR)","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"250 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"ETU350","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"250 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LSI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"25 000","Type Of Electrical Connection / For Main Current Circuit":"on both sides nut keeper kit","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=480981&mlfb=3VA2225-6HN32-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2225-6HN32-0DA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2225-6HN32-0DA0?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time."},{"question":"Will 3VA2225-6HN32-0DA0 drop into a panel specified around 3VA1112-5EE32-0AA0 without rewiring?","answer":"The 105 mm width and 181 mm height are standard for the 3VA frame family, so panel cutouts and bus connections for the 3VA1112-5EE32-0AA0 should accept this unit. Verify the depth (86 mm) and terminal layout against your existing bus bars."},{"question":"What compliance documentation does this brand provide for 3VA2225-6HN32-0DA0?","answer":"As a Siemens SENTRON product, it carries CE marking for the European market and is designed to meet IEC 60947-2. UL and CSA listings are typical for this series, but confirm the specific certification mark on the nameplate for your jurisdiction."},{"question":"What is the breaking capacity of 3VA2225-6HN32-0DA0 at 415 V?","answer":"187 kA at 415 V AC, which is the same rating as at 440 V."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2225-6HN32-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2225-6HN32-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}