{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2225-6JQ32-0CH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2225-6JQ32-0CH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2225-6JQ32-0CH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2225-6JQ32-0CH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2225-6JQ32-0CH0, molded case circuit breaker, 3-pole, 250 A, breaking capacity 242 kA at 240 V AC, ETU560 electronic trip unit, undervoltage release, communication capable.","salesMarkdown":"The Siemens 3VA2225-6JQ32-0CH0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current of 250 A at 40 °C and an insulation voltage of 800 V. That 250 A figure holds flat through 50 °C — only at 55 °C does it start to taper (238 A), dropping to 200 A at 70 °C. For a panel that runs warm, the full rating is available up to 50 °C ambient without derating. Breaking capacity is the standout: 242 kA at 240 V, 187 kA at 415 V, 121 kA at 500 V, and still 6 kA at 690 V. ## Trip unit, auxiliaries, and communication The overcurrent release is an ETU560 electronic trip unit — adjustable long-time, short-time, instantaneous, and ground-fault protection. Ground-fault monitoring uses summation current formation on the L-conductor. Communication function is built in — this variant is ready for integration into a higher-level monitoring system without an external comm module. The depth is 86 mm, which fits most standard distribution boards. Mechanical endurance is rated at 20,000 operations.","metaTitle":"Siemens 3VA2225-6JQ32-0CH0 MCCB, 250 A, 242 kA at 240 V","metaDescription":"Siemens SENTRON 3VA2225-6JQ32-0CH0 molded case circuit breaker, 250 A rated current, 242 kA breaking capacity at 240 V. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"6 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"238 A","at 60 °C":"225 A","at 65 °C":"213 A","at 70 °C":"200 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"Yes","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"50.5 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"250 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2225-6JQ32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Summation current formation L-conductor","Of The Integrated Auxiliary Trip":"3VA9608-0BB24","Design of the overcurrent release":"ETU560","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"15","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"250 A","Adjustable response value current / lg max.":"250 A","Adjustable response value current / lg min.":"50 A","Adjustable response value current / li max.":"2 500 A","Adjustable response value current / li min.":"375 A","Adjustable response value current / lr min.":"100 A","Adjustable response value current / Isd max.":"2 500 A","Adjustable response value current / Isd min.":"150 A","Ground fault protection can be switched ON/OFF":"Yes","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LSIG","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"250 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=391641&mlfb=3VA2225-6JQ32-0CH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2225-6JQ32-0CH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2225-6JQ32-0CH0 and how do I get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."},{"question":"What is 3VA2225-6JQ32-0CH0's listed depth?","answer":"The depth is 86 mm."},{"question":"What is 3VA2225-6JQ32-0CH0's listed width?","answer":"The width is 105 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2225-6JQ32-0CH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2225-6JQ32-0CH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}