{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2225-6KP32-0HC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2225-6KP32-0HC0","canonicalUrl":"https://aoctrl.com/siemens/3VA2225-6KP32-0HC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2225-6KP32-0HC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2225-6KP32-0HC0, molded case circuit breaker, 3-pole, 250 A (40-50 °C), ETU850 electronic trip unit, 242 kA at 240 V, 187 kA at 415 V, shunt trip STL, 2 HQ auxiliary switches, 86 mm depth.","salesMarkdown":"The Siemens 3VA2225-6KP32-0HC0 is a SENTRON molded case circuit breaker rated for 250 A continuous current from 40 °C through 50 °C, then derating to 200 A at 70 °C. Three poles, line-protection version with an ETU850 electronic trip unit. At 690 V it still clears 6 kA, so it handles the low-side of a 690 V drive line. The ETU850 release gives you communication and other measurement functions, so it can report trip data and load current over the bus. No undervoltage release, no ground-fault module on this variant. The 3VA2225-6KP32-0HC0 footprint is 105 mm wide by 86 mm deep by 181 mm tall. That's a standard 3-pole MCCB slot in most SENTRON distribution panels.","metaTitle":"Siemens 3VA2225-6KP32-0HC0 SENTRON MCCB, 250 A, 3-pole, ETU8","metaDescription":"Siemens 3VA2225-6KP32-0HC0 SENTRON molded case circuit breaker, 250 A rated at 40-50°C, 3-pole, ETU850 release, 242 kA at 240 V. Current lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"242 kA","at 415 V":"187 kA","at 440 V":"187 kA","at 500 V":"121 kA","at 690 V":"6 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"238 A","at 60 °C":"225 A","at 65 °C":"213 A","at 70 °C":"200 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"No","Communication Function":"Yes","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"48 W","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"Yes","Rated continuous current Iu":"250 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2225-6KP32-0AA0","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL30","Design of the overcurrent release":"ETU850","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"15","Adjustable response value time / tr min.":"0.5","Adjustable response value time / tsd max.":"0.5 s","Adjustable response value time / tsd min.":"0.05 s","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"250 A","Adjustable response value current / li max.":"2 500 A","Adjustable response value current / li min.":"375 A","Adjustable response value current / lr min.":"100 A","Adjustable response value current / Isd max.":"2 500 A","Adjustable response value current / Isd min.":"150 A","Neutral conductors / upgradeable/retrofittable":"Yes","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LSI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"250 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=332796&mlfb=3VA2225-6KP32-0HC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2225-6KP32-0HC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA2225-6KP32-0HC0 and how do I get a price?","answer":"This part is sourced through independent distribution and quoted to order against an RFQ. Submit a request for current pricing and availability — no stock count or lead-time figure is published here."},{"question":"What are the key interrupting ratings for this MCCB?","answer":"At 240 V it clears 242 kA; at 415 V and 440 V it clears 187 kA; at 500 V it clears 121 kA; at 690 V it clears 6 kA. The rated continuous current is 250 A from 40 °C through 50 °C, derating to 200 A at 70 °C."},{"question":"What trip unit and accessories does this breaker include?","answer":"It has an ETU850 electronic overcurrent release with communication and measurement functions, a shunt trip (STL), and two HQ auxiliary switches. No undervoltage release or ground-fault module is fitted on this variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2225-6KP32-0HC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2225-6KP32-0HC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}