{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA2225-7HL32-0CH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA2225-7HL32-0CH0","canonicalUrl":"https://aoctrl.com/siemens/3VA2225-7HL32-0CH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA2225-7HL32-0CH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA2225-7HL32-0CH0, molded case circuit breaker, 3-pole, 250 A rated continuous current, line protection, ETU320 electronic trip unit, with undervoltage release and auxiliary switches.","salesMarkdown":"That 250 A holds flat from 40 °C through 50 °C ambient — no derating needed in a typical warm panel — then steps down to 241 A at 55 °C, 232 A at 60 °C, 222 A at 65 °C, and 213 A at 70 °C. So if your enclosure runs hot, you still have a solid 213 A of headroom at the upper end of the operating range. The interrupting ratings tell you where this breaker can sit in the fault-current chain: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 6.3 kA at 690 V. That 330 kA at 240 V is a main or large-feeder class rating; the 6.3 kA at 690 V still covers most industrial loads at that voltage. The integrated auxiliary trip module is order code 3VA9608-0BB24; the supplied basic switch is 3VA2225-7HL32-0AA0. ## Mounting and integration into a 3-pole footprint Maximum power loss is 50.5 W. Trip indicator is present. ## How this compares to the 3VA1112-5EF32-0CA0 The 3VA1112-5EF32-0CA0 is a smaller-frame SENTRON MCCB — lower continuous current, different trip unit, and a narrower width. It will not drop into the same panel cutout or bus connection as this 3VA2225-7HL32-0CH0 without rewiring and re-bussing. The 3VA2225 is the 250 A frame; the 3VA1112 is a 160 A or lower frame. If your BOM calls for the 250 A rating, the 3VA1112 is not a functional second-source — you need the 3VA2225 frame.","metaTitle":"Siemens 3VA2225-7HL32-0CH0 SENTRON MCCB, 250 A, 3-Pole, Line","metaDescription":"Siemens SENTRON 3VA2225-7HL32-0CH0 molded case circuit breaker, 250 A rated continuous current, 3-pole, line protection, ETU320 release. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"181 mm","at 240 V":"330 kA","at 415 V":"242 kA","at 440 V":"242 kA","at 500 V":"187 kA","at 690 V":"6.3 kA","at 40 °C":"250 A","at 45 °C":"250 A","at 50 °C":"250 A","at 55 °C":"241 A","at 60 °C":"232 A","at 65 °C":"222 A","at 70 °C":"213 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"20 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"50.5 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"250 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA2225-7HL32-0AA0","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB24","Design of the overcurrent release":"ETU320","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"15","Adjustable response value time / tr min.":"0.5","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"250 A","Adjustable response value current / li max.":"2 500 A","Adjustable response value current / li min.":"375 A","Adjustable response value current / lr min.":"100 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"C","Max. rated operational current of the frame size":"250 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"25 x 8.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"13 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a7c0d29262bf1366bc093fc9653b1e6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=480936&mlfb=3VA2225-7HL32-0CH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA2225-7HL32-0CH0/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this brand provide for 3VA2225-7HL32-0CH0?","answer":"As a Siemens SENTRON product, this MCCB carries the standard IEC/UL certifications for molded case circuit breakers. Specific compliance documentation (RoHS, REACH, UL, IEC) is available on request at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA2225-7HL32-0CH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA2225-7HL32-0CH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}